Recent advances in graphene based electrochemical glucose sensor
R Reghunath, KK Singh - Nano-Structures & Nano-Objects, 2021 - Elsevier
The electrochemical detection of glucose concentration without using enzymes have
recently created overwhelming demand in the field of glucose sensors. The demand to …
recently created overwhelming demand in the field of glucose sensors. The demand to …
Nickel as a catalyst for the electro-oxidation of methanol in alkaline medium
MAA Rahim, RMA Hameed, MW Khalil - Journal of power sources, 2004 - Elsevier
The use of Ni as a catalyst for the electro-oxidation of methanol in alkaline medium was
studied by cyclic voltammetry. It was found that only Ni dispersed on graphite shows a …
studied by cyclic voltammetry. It was found that only Ni dispersed on graphite shows a …
The hydrogen evolution reaction on nickel surfaces stabilized by H-absorption
SAS Machado, LA Avaca - Electrochimica acta, 1994 - Elsevier
The hydrogen evolution reaction (her) was studied on bright nickel electrodes in alkaline
solutions at several temperatures. The formation of nickel hydrides in the potential region of …
solutions at several temperatures. The formation of nickel hydrides in the potential region of …
A highly sensitive non-enzymatic glucose sensor based on nickel and multi-walled carbon nanotubes nanohybrid films fabricated by one-step co-electrodeposition in …
A Sun, J Zheng, Q Sheng - Electrochimica Acta, 2012 - Elsevier
In this paper, nickel was combined with multi-walled carbon nanotubes (Ni–MWNTs) to
fabricate nanohybrid films on a conventional glassy carbon electrode using simultaneous …
fabricate nanohybrid films on a conventional glassy carbon electrode using simultaneous …
In situ UV visible reflectance spectroscopic investigation of the nickel electrode-alkaline solution interface
F Hahn, B Beden, MJ Croissant, C Lamy - Electrochimica acta, 1986 - Elsevier
An in situ uv visible reflectance spectroscopic technique is used to investigate the nickel
electrode-alkaline solution interface. It is shown that by recording the change in relative …
electrode-alkaline solution interface. It is shown that by recording the change in relative …
The non-enzymatic determination of glucose using an electrolytically fabricated nickel microparticle modified boron-doped diamond electrode or nickel foil electrode
KE Toghill, L Xiao, MA Phillips, RG Compton - Sensors and actuators B …, 2010 - Elsevier
A nickel modified boron-doped diamond (Ni-BDD) electrode or nickel foil electrode were
used in the non-enzymatic determination of glucose in alkaline solutions. The Ni-BDD …
used in the non-enzymatic determination of glucose in alkaline solutions. The Ni-BDD …
The potentiodynamic behaviour of iron in alkaline solutions
The potentiodynamic behaviour of iron in alkaline solutions under carefully controlled
perturbation conditions reveals that the overall electrochemical process is more involved …
perturbation conditions reveals that the overall electrochemical process is more involved …
Electrochemical determination of sulphide at nickel electrodes in alkaline media: a new electrochemical sensor
D Giovanelli, NS Lawrence, L Jiang, TGJ Jones… - Sensors and Actuators B …, 2003 - Elsevier
The electrochemistry of a nickel hydroxide electrode has been studied both in the presence
and absence of sulphide at microdisc and macroelectrodes. With sulphide present a new …
and absence of sulphide at microdisc and macroelectrodes. With sulphide present a new …
Ni–P and Ni–Cu–P modified carbon catalysts for methanol electro-oxidation in KOH solution
RMA Hameed, KM El-Khatib - international journal of hydrogen energy, 2010 - Elsevier
The electrocatalytic oxidation of methanol was studied on Ni–P and Ni–Cu–P supported
over commercial carbon electrodes in 0.1 M KOH solution. Cyclic voltammetry and …
over commercial carbon electrodes in 0.1 M KOH solution. Cyclic voltammetry and …
Surface characterization of Co3O4 electrodes prepared by the sol-gel method
G Spinolo, S Ardizzone, S Trasatti - Journal of Electroanalytical Chemistry, 1997 - Elsevier
Co3O4 layers on an Ni support were prepared by the sol-gel method. Their properties were
characterized by TGA, XRD and SEM. For comparison, Co3O4 was also prepared by …
characterized by TGA, XRD and SEM. For comparison, Co3O4 was also prepared by …