Revision of the 252Cf and D2O-moderated 252Cf reference neutron fields for use in radiation protection dosimetry

R Méndez, JM Gómez-Ros, DJ Thomas… - Radiation Physics and …, 2021 - Elsevier
Abstract ISO Standard 8529–1: 2001 on Reference neutron radiations is under revision. The
spectral data for the D 2 O-moderated 252 Cf field in the 2001 version of the standard refer …

Analytical evaluation of geometry correction factor and effectiveness parameter for BSS irradiated by a voluminous neutron source

M Yousefi, R Khabaz - Radiation Physics and Chemistry, 2022 - Elsevier
The deviation in reading due to inverse square law is an important issue in the calibration of
neutron detection systems. The geometry correction factor of a neutron-measuring device is …

Development of lightweight portable neutron survey meter

T Nunomiya, T Nakamura, S Yamamura… - Journal of Nuclear …, 2017 - Taylor & Francis
We have developed a lightweight portable neutron survey meter comprising a proportional
gas counter containing a mixed gas of methane gas and nitrogen gas for measuring the …

Distance-dependency of the D2O-moderated 252Cf spectrum and influence on the calibration factors

M Yousefi, R Khabaz - Radiation Physics and Chemistry, 2021 - Elsevier
Abstract The D 2 O-moderated 252 Cf is a non-point neutron source used as a calibration
facility for measuring devices. The Bonner spheres spectrometer (BSS) is one of the …

[PDF][PDF] Development of a neutron standard field using a heavy-water moderated 252Cfsource at NMI1-AIST

A Masuda, H Harano, T Matsumoto, K Kudo… - Prog. Nucl. Sci …, 2014 - aesj.net
A neutron standard field using a heavy-water moderated 252Cf source has been developed
at the National Metrology Institute of Japan, National Institute of Advanced Industrial Science …

An Inter-comparison of the Neutron Calibration Fields by D2O Moderated 252Cf Source at JAEA and KAERI

M Kowatari, K Fujii, M Tsutsumi, BH Kim… - Journal of Nuclear …, 2008 - Taylor & Francis
An inter-comparison of the neutron calibration field of the D2O moderated 252Cf source was
carried out at JAEA and KAERI. Measuring the neutron spectra at KAERI by means of the …

[PDF][PDF] Evaluation of the neutron response of a criticality accident alarm system detector

N Tsujimura, T Yoshida - Prog. Nucl. Sci. Technol, 2014 - researchgate.net
A neutron irradiation experiment was performed to determine the neutron absorbed dose
rate response of a criticality accident alarm system detector. For this purpose, the authors …

[PDF][PDF] Development of Two Types of Lightweight Portable Neutron Survey Meter

T Nunomiya, T Nakamura - Datess, 2022 - scientificeminencegroup.com
We have developed two types of lightweight active portable neutron survey meter
comprising a proportional gas counter with a mixture of methane and nitrogen for measuring …

Development of a new type of manganese bath for determination of neutron emission rate of a neutron source

T Matsumoto, H Harano, A Masuda… - 2014 IEEE Nuclear …, 2014 - ieeexplore.ieee.org
We are developing a new type of manganese bath for determination of neutron emission
rate of a radioactive neutron source. The manganese bath gas a multilayered structure …

[PDF][PDF] DEVELOPMENT OF AN ENERGY AND DIRECTIONAL INDEPENDENT NEUTRON DOSE MONITOR

SH Bhuiya, H Yamanishi, T Uda, N Sultana… - Vol. 30 December … - bina.portal.gov.bd
An energy and directional independent neutron ambient dose equivalent monitor was