Present and future of gait assessment in clinical practice: Towards the application of novel trends and technologies

AA Hulleck, D Menoth Mohan, N Abdallah… - Frontiers in medical …, 2022 - frontiersin.org
Background Despite being available for more than three decades, quantitative gait analysis
remains largely associated with research institutions and not well leveraged in clinical …

Applications and limitations of current markerless motion capture methods for clinical gait biomechanics

L Wade, L Needham, P McGuigan, J Bilzon - PeerJ, 2022 - peerj.com
Background Markerless motion capture has the potential to perform movement analysis with
reduced data collection and processing time compared to marker-based methods. This …

The accuracy of several pose estimation methods for 3D joint centre localisation

L Needham, M Evans, DP Cosker, L Wade… - Scientific reports, 2021 - nature.com
Human movement researchers are often restricted to laboratory environments and data
capture techniques that are time and/or resource intensive. Markerless pose estimation …

The extensibility of the plantar fascia influences the windlass mechanism during human running

L Welte, LA Kelly, SE Kessler… - … of the Royal …, 2021 - royalsocietypublishing.org
The arch of the human foot is unique among hominins as it is compliant at ground contact
but sufficiently stiff to enable push-off. These behaviours are partly facilitated by the …

[HTML][HTML] The development and evaluation of a fully automated markerless motion capture workflow

L Needham, M Evans, L Wade, DP Cosker… - Journal of …, 2022 - Elsevier
This study presented a fully automated deep learning based markerless motion capture
workflow and evaluated its performance against marker-based motion capture during …

Comparison of kinematics between Theia markerless and conventional marker-based gait analysis in clinical patients

TAL Wren, P Isakov, SA Rethlefsen - Gait & Posture, 2023 - Elsevier
Background Markerless motion capture systems have the potential to make clinical gait
analysis more efficient and convenient. Theia3D is a commercially available markerless …

Human foot form and function: variable and versatile, yet sufficiently related to predict function from form

RW Schuster, AG Cresswell… - Proceedings of the …, 2024 - royalsocietypublishing.org
The human foot is a complex structure that plays an important role in our capacity for upright
locomotion. Comparisons of our feet with those of our closest extinct and extant relatives …

Comparison of joint load, motions and contact stress and bone‐implant interface micromotion of three implant designs for total ankle arthroplasty

Y Zhang, Z Chen, H Zhao, D Zhao, X Zhang… - Computer Methods and …, 2022 - Elsevier
Abstract Background and Objective Loosening and wear are still the main problems for the
failure of total ankle arthroplasty, which are closely related to the micromotion at the bone …

[HTML][HTML] The influence of soft tissue artifacts on multi-segment foot kinematics

W Schallig, GJ Streekstra, CM Hulshof… - Journal of …, 2021 - Elsevier
Movement of skin markers with respect to their underlying bone (ie soft tissue artifacts
(STAs)) might corrupt the accuracy of marker-based movement analyses. This study aims to …

[HTML][HTML] Comparing the kinematic output of the Oxford and Rizzoli Foot Models during normal gait and voluntary pathological gait in healthy adults

W Schallig, JC van den Noort, J McCahill, J Stebbins… - Gait & Posture, 2020 - Elsevier
Abstract Background The Oxford Foot Model (OFM) and Rizzoli Foot Model (RFM) are the
two most frequently used multi-segment models to measure foot kinematics. However, a …