[HTML][HTML] Cardiovascular magnetic resonance phase contrast imaging

KS Nayak, JF Nielsen, MA Bernstein, M Markl… - Journal of …, 2015 - Elsevier
Cardiovascular magnetic resonance (CMR) phase contrast imaging has undergone a wide
range of changes with the development and availability of improved calibration procedures …

Applications of phase-contrast flow and velocity imaging in cardiovascular MRI

PD Gatehouse, J Keegan, LA Crowe, S Masood… - European …, 2005 - Springer
A review of cardiovascular clinical and research applications of MRI phase-contrast velocity
imaging, also known as velocity mapping or flow imaging. Phase-contrast basic principles …

Calcified coronary artery plaque measurement with cardiac CT in population-based studies: standardized protocol of Multi-Ethnic Study of Atherosclerosis (MESA) and …

JJ Carr, JC Nelson, ND Wong, M McNitt-Gray, Y Arad… - Radiology, 2005 - pubs.rsna.org
Calcified coronary artery plaque, measured at cardiac computed tomography (CT), is a
predictor of cardiovascular disease and may play an increasing role in cardiovascular …

In-plane coronary arterial motion velocity: measurement with electron-beam CT

S Achenbach, D Ropers, J Holle, G Muschiol… - Radiology, 2000 - pubs.rsna.org
PURPOSE: To determine the speed of and changes in the speed of coronary arterial
movement during the cardiac cycle with electron-beam computed tomography (CT) …

ECG-gated reconstructed multi–detector row CT coronary angiography: effect of varying trigger delay on image quality

C Hong, CR Becker, A Huber, UJ Schoepf… - Radiology, 2001 - pubs.rsna.org
PURPOSE: To evaluate the effectiveness of electrocardiographically (ECG)-gated
retrospective image reconstruction for multi–detector row computed tomographic (CT) …

Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging

RM Botnar, M Stuber, KV Kissinger, WY Kim… - Circulation, 2000 - Am Heart Assoc
Background—Conventional x-ray angiography frequently underestimates the true burden of
atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque …

Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection

T Giesler, U Baum, D Ropers… - American Journal of …, 2002 - Am Roentgen Ray Soc
OBJECTIVE. Although multidetector CT (MDCT) with retrospectively ECG-gated image
reconstruction has been shown to permit noninvasive visualization of the coronary arteries …

Motion in Cardiovascular MR Imaging1

AD Scott, J Keegan, DN Firmin - Radiology, 2009 - pubs.rsna.org
Modern rapid magnetic resonance (MR) imaging techniques have led to widespread use of
the modality in cardiac imaging. Despite this progress, many MR studies suffer from image …

Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography

Y Wang, E Vidan, GW Bergman - Radiology, 1999 - pubs.rsna.org
PURPOSE: To measure the duration of the rest period in the cardiac cycle, a parameter vital
to data acquisition in coronary magnetic resonance (MR) angiography. MATERIALS AND …

Coronary Artery Motion and Cardiac Phases: Dependency on Heart Rate—Implications for CT Image Reconstruction1

L Husmann, S Leschka, L Desbiolles, T Schepis… - Radiology, 2007 - pubs.rsna.org
This study had institutional review board approval; written informed consent was obtained.