Flexural damage diagnosis in reinforced concrete beams using a wireless admittance monitoring system—Tests and finite element analysis
The utilization and effectiveness of a custom-made, portable and low-cost structural health
monitoring (SHM) system that implements the PZT-based electro-mechanical admittance …
monitoring (SHM) system that implements the PZT-based electro-mechanical admittance …
Structural health monitoring of seismically vulnerable RC frames under lateral cyclic loading
CE Chalioris, ME Voutetaki… - Earthquakes and …, 2020 - koreascience.kr
The effectiveness and the sensitivity of a Wireless impedance/Admittance Monitoring System
(WiAMS) for the prompt damage diagnosis of two single-storey single-span Reinforced …
(WiAMS) for the prompt damage diagnosis of two single-storey single-span Reinforced …
Electromechanical impedance instrumented wearable piezoelectric ring-type sensor for bolted connection monitoring
Due to the loss of preload, structural failure caused by bolt loosening is common in
engineering structures. Effective monitoring of bolted connections is of great importance in …
engineering structures. Effective monitoring of bolted connections is of great importance in …
Local dynamic characteristics of PZT impedance interface on tendon anchorage under prestress force variation
TC Huynh, KS Lee, JT Kim - Smart structures and systems, 2015 - dbpia.co.kr
In this study, local dynamic characteristics of mountable PZT interfaces are numerically
analyzed to verify their feasibility on impedance monitoring of the prestress-loss in tendon …
analyzed to verify their feasibility on impedance monitoring of the prestress-loss in tendon …
Application of an improved damage detection method for building structures based on ambient vibration measurements
This paper presents a novel modal contribution-based damage identification system for low-
to medium-rise buildings with simple and regular geometries using multi-step ambient …
to medium-rise buildings with simple and regular geometries using multi-step ambient …
[HTML][HTML] Temperature effect on wireless impedance monitoring in tendon anchorage of prestressed concrete girder
JH Park, TC Huynh, JT Kim - Smart structures and systems, 2015 - koreascience.kr
In this study, the effect of temperature variation on the wireless impedance monitoring is
analyzed for the tendon-anchorage connection of the prestressed concrete girder. Firstly …
analyzed for the tendon-anchorage connection of the prestressed concrete girder. Firstly …
An Innovative Health-Monitoring Approach for Fiber-Reinforced Polymer Debonding Diagnosis Through Pullout and Shear Tests
The need for rehabilitation of Reinforced Concrete (RC) structures is highlighted by the
increased requirements for adequate resistance to seismic actions. Recently, a novel Fiber …
increased requirements for adequate resistance to seismic actions. Recently, a novel Fiber …
Health assessment of RC building subjected to ambient excitation: Strategy and application
Abstract Structural Health Monitoring (SHM) is used to provide reliable information about the
structure's integrity in near realtime following extreme incidents such as earthquakes …
structure's integrity in near realtime following extreme incidents such as earthquakes …