[HTML][HTML] Hypersensitivity Reactions to Components of Cardiac Implantable Electronic Devices and Their Treatment: A Systematic Review

E Kealaher, P Shah, T Dissanayake… - Arrhythmia & …, 2023 - ncbi.nlm.nih.gov
Background: Hypersensitivity reactions (HSRs) to components of cardiac implantable
electronic devices (CIEDs) are rare but difficult to differentiate from device infection. Data on …

Hypersensitivity to Implanted Metal Devices

BL Schwartz, DJ Pithadia, JK Chen - Current Dermatology Reports, 2023 - Springer
Abstract Purpose of Review Metal implants play a significant role in modern medicine. This
review summarizes the current literature regarding metal implant hypersensitivity reactions …

Cardiac implantable electronic devices (CIED s) and allergy

E De Ruvo, M Petrungaro, L De Luca… - Journal of …, 2023 - Wiley Online Library
Advances in cardiac implantable electronic devices (CIEDs) have prolonged life expectancy
in various medical settings. However, the issue of hypersensitivity to components of CIEDs is …

[HTML][HTML] First-in-man implantation of a gold-coated biventricular defibrillator: difficult differential diagnosis of metal hypersensitivity reaction vs chronic device infection

DG Meininghaus, J Kruells-Muench… - HeartRhythm Case …, 2020 - Elsevier
Regardless of the success story of cardiac pacing, the majority of the delayed complications
of cardiac device implantations are systemic infections. The incidence of pacemaker …

Too Late Allergic Reaction in a Patient with Permanent Pacemaker.

F Akkuş, G Taylan - Archives of the Turkish Society of …, 2022 - search.ebscohost.com
English Contact allergy to cardiac implantable electronic devices is a rare problem in
patients. Clinical evaluation and patch tests have an important place in its diagnosis. Also in …

[HTML][HTML] A method for successfully implanting an implantable cardioverter-defibrillator wrapped with an expanded polytetrafluoroethylene sheet in a patient with metal …

K Morishita, A Ishihara, T Unno, T Murakami… - Journal of Cardiology …, 2023 - Elsevier
Contact dermatitis is a severe complication of cardiac-device implantation that may be
observed in patients with metal allergies. Some studies have suggested that wrapping …

Hypersensitivity to cardiovascular implants: cardiac implantable electronic devices and septal occluders

G Honari, F Raissi - Metal Allergy: From Dermatitis to Implant and Device …, 2018 - Springer
The increasing application of medical devices in the management of various medical and
surgical conditions and introduction of various implantable biomedical devices comes with …

[PDF][PDF] Ocena częstości występowania powikłań o typie skórnej reakcji alergicznej lub systemowej reakcji nadwrażliwości u pacjentów z urządzeniami wszczepialnymi …

M Wujkowski, P Lipiec - Alergoprofil, 2019 - journalsmededu.pl
For non- commercial use only Page 1 3 PRACA ORYGINALNA Ocena częstości
występowania powikłań o typie skórnej reakcji alergicznej lub systemowej reakcji …

[引用][C] Local release of metal ions from endovascular metallic implants in the human biological specimens: An overview of in vivo clinical implications

H Matusiewicz, M Richter - World Journal …, 2021 - World Journal of Advanced …

ePTFE でペースメーカーを被覆して植込んだ金属アレルギー患者の1 例

鎌田啓輔, 眞岸克明, 清水紀之, 和泉裕一 - 日本臨床外科学会雑誌, 2018 - jstage.jst.go.jp
抄録 症例は 72 歳, 女性. 高血圧, 脂質異常症, 洞不全症候群で近医に通院中であった. Holter
心電図で約 10 秒間の long pause を認めたため, ペースメーカー (PM) 植込みを目的に当院へ …