Differential sampling measurement of a 7 V RMS sine wave with a programmable Josephson voltage standard

A Rüfenacht, CJ Burroughs… - IEEE Transactions …, 2013 - ieeexplore.ieee.org
A 10 V programmable Josephson voltage standard has enabled sine waves with voltages
up to 7 V RMS to be accurately measured with a differential sampling measurement …

Impact of the latest generation of Josephson voltage standards in ac and dc electric metrology

A Rüfenacht, NE Flowers-Jacobs, SP Benz - Metrologia, 2018 - iopscience.iop.org
For decades, the quantum behavior of Josephson junctions has been employed as intrinsic
standards for voltage metrology. Conventional dc Josephson voltage standards have been …

Development and metrological applications of Josephson arrays at PTB

R Behr, O Kieler, J Kohlmann, F Müller… - Measurement Science …, 2012 - iopscience.iop.org
The discovery of the Josephson effects 50 years ago initiated a revolution for electrical
voltage metrology. This revolution started with single Josephson junctions delivering a few …

An ac quantum voltmeter based on a 10 V programmable Josephson array

J Lee, R Behr, L Palafox, A Katkov, M Schubert… - Metrologia, 2013 - iopscience.iop.org
An ac quantum voltmeter based on a 10 V programmable Josephson array that is simple to
use, provides dc and ac calibration up to kHz range for equipment widely used in metrology …

Characterization of metrological grade analog-to-digital converters using a programmable Josephson voltage standard

F Overney, A Rufenacht, JP Braun… - IEEE Transactions …, 2011 - ieeexplore.ieee.org
A test bench has been developed for systematic characterization of high-resolution analog-
to-digital converters. The reference signal is generated by a programable Josephson …

$ RLC $ bridge based on an automated synchronous sampling system

F Overney, B Jeanneret - IEEE Transactions on Instrumentation …, 2011 - ieeexplore.ieee.org
An RLC bridge based on an automated synchronous sampling system has been developed
using commercially available high-resolution analog-to-digital and digital-to-analog …

Direct comparison of a 1 V Josephson arbitrary waveform synthesizer and an ac quantum voltmeter

R Behr, O Kieler, J Lee, S Bauer, L Palafox… - Metrologia, 2015 - iopscience.iop.org
AC Josephson voltage standards based on pulse-driven Josephson arrays (Josephson
arbitrary waveform synthesizer—JAWS) have recently achieved an output voltage of at least …

An AC Josephson voltage standard up to the kilohertz range tested in a calibration laboratory

M Schubert, M Starkloff, J Lee, R Behr… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
This paper describes the development of an automated ac quantum voltmeter toward a
turnkey system, which can be used for calibration of common dc and ac voltage standards …

An AC quantum voltmeter for frequencies up to 100 kHz using sub-sampling

R Behr, L Palafox - Metrologia, 2021 - iopscience.iop.org
Differential sampling relative to a Josephson waveform, the ac quantum voltmeter (ac-QVM),
has been established as the most accurate method for measuring signals below 1 kHz with …

Direct comparison of two NIST PJVS systems at 10 V

S Solve, A Rüfenacht, CJ Burroughs, SP Benz - Metrologia, 2013 - iopscience.iop.org
Two NIST programmable Josephson voltage standard (PJVS) systems are directly
compared at 10 V using different nanovoltmeters. These PJVS systems use arrays of triple …