Differential sampling measurement of a 7 V RMS sine wave with a programmable Josephson voltage standard
A Rüfenacht, CJ Burroughs… - IEEE Transactions …, 2013 - ieeexplore.ieee.org
A 10 V programmable Josephson voltage standard has enabled sine waves with voltages
up to 7 V RMS to be accurately measured with a differential sampling measurement …
up to 7 V RMS to be accurately measured with a differential sampling measurement …
Impact of the latest generation of Josephson voltage standards in ac and dc electric metrology
For decades, the quantum behavior of Josephson junctions has been employed as intrinsic
standards for voltage metrology. Conventional dc Josephson voltage standards have been …
standards for voltage metrology. Conventional dc Josephson voltage standards have been …
Development and metrological applications of Josephson arrays at PTB
R Behr, O Kieler, J Kohlmann, F Müller… - Measurement Science …, 2012 - iopscience.iop.org
The discovery of the Josephson effects 50 years ago initiated a revolution for electrical
voltage metrology. This revolution started with single Josephson junctions delivering a few …
voltage metrology. This revolution started with single Josephson junctions delivering a few …
An ac quantum voltmeter based on a 10 V programmable Josephson array
J Lee, R Behr, L Palafox, A Katkov, M Schubert… - Metrologia, 2013 - iopscience.iop.org
An ac quantum voltmeter based on a 10 V programmable Josephson array that is simple to
use, provides dc and ac calibration up to kHz range for equipment widely used in metrology …
use, provides dc and ac calibration up to kHz range for equipment widely used in metrology …
Characterization of metrological grade analog-to-digital converters using a programmable Josephson voltage standard
F Overney, A Rufenacht, JP Braun… - IEEE Transactions …, 2011 - ieeexplore.ieee.org
A test bench has been developed for systematic characterization of high-resolution analog-
to-digital converters. The reference signal is generated by a programable Josephson …
to-digital converters. The reference signal is generated by a programable Josephson …
$ RLC $ bridge based on an automated synchronous sampling system
F Overney, B Jeanneret - IEEE Transactions on Instrumentation …, 2011 - ieeexplore.ieee.org
An RLC bridge based on an automated synchronous sampling system has been developed
using commercially available high-resolution analog-to-digital and digital-to-analog …
using commercially available high-resolution analog-to-digital and digital-to-analog …
Direct comparison of a 1 V Josephson arbitrary waveform synthesizer and an ac quantum voltmeter
R Behr, O Kieler, J Lee, S Bauer, L Palafox… - Metrologia, 2015 - iopscience.iop.org
AC Josephson voltage standards based on pulse-driven Josephson arrays (Josephson
arbitrary waveform synthesizer—JAWS) have recently achieved an output voltage of at least …
arbitrary waveform synthesizer—JAWS) have recently achieved an output voltage of at least …
An AC Josephson voltage standard up to the kilohertz range tested in a calibration laboratory
M Schubert, M Starkloff, J Lee, R Behr… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
This paper describes the development of an automated ac quantum voltmeter toward a
turnkey system, which can be used for calibration of common dc and ac voltage standards …
turnkey system, which can be used for calibration of common dc and ac voltage standards …
An AC quantum voltmeter for frequencies up to 100 kHz using sub-sampling
R Behr, L Palafox - Metrologia, 2021 - iopscience.iop.org
Differential sampling relative to a Josephson waveform, the ac quantum voltmeter (ac-QVM),
has been established as the most accurate method for measuring signals below 1 kHz with …
has been established as the most accurate method for measuring signals below 1 kHz with …
Direct comparison of two NIST PJVS systems at 10 V
Two NIST programmable Josephson voltage standard (PJVS) systems are directly
compared at 10 V using different nanovoltmeters. These PJVS systems use arrays of triple …
compared at 10 V using different nanovoltmeters. These PJVS systems use arrays of triple …