[HTML][HTML] Firefly algorithm based solution to minimize the real power loss in a power system
P Balachennaiah, M Suryakalavathi… - Ain Shams Engineering …, 2018 - Elsevier
This paper proposes a method to minimize the real power loss (RPL) of a power system
transmission network using a new meta-heuristic algorithm known as firefly algorithm (FA) …
transmission network using a new meta-heuristic algorithm known as firefly algorithm (FA) …
Development of optimal shunt hybrid compensator based on improving the measurement of various signals
MT Esfahani, B Vahidi - Measurement, 2015 - Elsevier
Voltage and current harmonics generated by nonlinear loads in power systems cause a
reduction in electric power quality (EPQ) which has recently become a serious …
reduction in electric power quality (EPQ) which has recently become a serious …
A standardized approach for evaluating UPFC's optimal location using metaheuristic algorithms to improve power quality
N Kalpana - 2022 International Conference on Electronics …, 2022 - ieeexplore.ieee.org
The development of Flexible AC Transmission System (FACTS) devices in electrical power
systems has increased over the past decade because of its multiple advantages like …
systems has increased over the past decade because of its multiple advantages like …
On‐line voltage security assessment and control
H Li, E Haq, K Abdul‐Rahman, J Wu… - … on Electrical Energy …, 2014 - Wiley Online Library
Voltage stability analysis and control are key applications for maintaining and enhancing the
voltage security of bulk power systems. In today's control center, as power systems become …
voltage security of bulk power systems. In today's control center, as power systems become …
Simplified voltage control of paralleling doubly fed induction generators connected to the network using SVC
Z Elhassan, Y Li, Y Tang - International Transactions on …, 2015 - Wiley Online Library
This paper presents a simplified voltage control of paralleling doubly fed induction
generators (DFIGs) connected to the grid by using static Var compensator (SVC). The DFIG …
generators (DFIGs) connected to the grid by using static Var compensator (SVC). The DFIG …
Implementation aspects and comprehensive assessment of a 16 MVAr static VAr compensator installed for a weak distribution network
AA Alabduljabbar, CÖ Gerçek, T Atalik… - … on Electrical Energy …, 2017 - Wiley Online Library
Voltage regulation at weak distribution networks and feeders imposes several challenges.
The degree of complexities of the overall design and implementation is network and site …
The degree of complexities of the overall design and implementation is network and site …
Proposta, modelagem e validação de uma nova concepção de regulador eletromagnético através do reforço série de tensão
FP Santilio - 2013 - repositorio.ufu.br
The search for solutions to the diverse problems associated with power quality, in particular
the regulation of the supply voltage, has been a source of various innovative proposals …
the regulation of the supply voltage, has been a source of various innovative proposals …
A study of the effect of power electronic system interaction with power system voltage stability
Voltage stability has of recent been a subject of growing concern to power system utilities. In
this paper, 2 techniques, one based on topological structure of power networks and the …
this paper, 2 techniques, one based on topological structure of power networks and the …
Voltage stability assessment of a power system incorporating FACTS in equivalent mode.
T Datta, P Nagendra, S Paul - Journal of Electrical …, 2013 - search.ebscohost.com
Two-bus network equivalent is commonly used to get a quick overview on the voltage
stability of a multi-bus power system. This paper presents a method to predict the voltage …
stability of a multi-bus power system. This paper presents a method to predict the voltage …
Assessment of the maximum loadability point of a power system after third zone of distance relay corrective actions
In this paper, the operation of a system and distance relay is improved during voltage
instability by using an improved strategy. After detecting the voltage instability, the third zone …
instability by using an improved strategy. After detecting the voltage instability, the third zone …