The development of an EM-field probing system for manual near-field scanning

H He, P Maheshwari… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
This research was conducted to visualize the frequency-dependent electromagnetic field
distribution for electromagnetic compatibility (EMC) applications and the time evolution of …

A simple frequency response compensation method for current probe measurements of ESD currents

S Yang, J Zhou, D Pommerenke… - 2017 IEEE International …, 2017 - ieeexplore.ieee.org
The transfer impedance of a current probe is typically not constant within the current probe's
operational frequency range. As it is based on induction, it will suffer from reduced sensitivity …

On the influence of humidity on the breakdown strength of air—with a case study on the PDIV of contacting enameled wire pairs

R Färber, O Šefl, CM Franck - Journal of Physics D: Applied …, 2023 - iopscience.iop.org
The partial discharge inception voltage (PDIV) in contacting enameled wire pairs exhibits a
marked decrease with increased air humidity. While existing literature mentions several …

Software-assisted detection methods for secondary ESD discharge during IEC 61000-4-2 testing

S Marathe, G Maghlakelidze, H Rezaei… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
When an electrostatic discharge (ESD) event reaches a nongrounded metallic part within a
product, the voltage of this metal with respect to ground will increase. If the isolation to the …

ESD Events to Wearable Medical Devices in Healthcare Environments—Part 1: Current Measurements

M Kohani, J Meiguni, DJ Pommerenke… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
Wearable medical devices are widely used for monitoring and treatment of patients.
Electrostatic discharge can render these devices unreliable and cause a temporary or …

Full-wave simulation of system-level disruption during secondary ESD events in a smartphone

DZ Li, S Marathe, P Wei, A Hosseinbeig… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
To demonstrate the electromagnetic full-wave simulation of a secondary electrostatic
discharge (ESD), an ESD generator is modeled in three dimensions (3D) and in contact …

On the frequency dependence of the PDIV in twisted pair magnet wire analogy in humid air

O Šefl, R Färber, CM Franck - Journal of Physics D: Applied …, 2024 - iopscience.iop.org
The partial discharge inception voltage (PDIV) of low-voltage induction motor turn-turn
insulation analogy is investigated for variable relative humidity (RH) of the surrounding air …

Stochastic modeling of air electrostatic discharge parameters

Y Xiu, S Sagan, A Battini, X Ma… - 2018 IEEE …, 2018 - ieeexplore.ieee.org
An automated tester is built for IEC 61000-4-2 air discharges. The relations between the
parameters of the resulting waveforms are studied using stochastic modeling. The …

On secondary ESD event monitoring and full-wave modeling methodology

S Marathe, D Li, A Hosseinbeig… - 2017 39th Electrical …, 2017 - ieeexplore.ieee.org
An adjustable spark gap structure is designed to generate Secondary ESD. The primary and
the secondary discharge current are directly measured. The setup is modelled using CST …

Secondary discharge-A potential risk during system level ESD testing

H Wolf, H Gieser - 2015 37th Electrical Overstress/Electrostatic …, 2015 - ieeexplore.ieee.org
By means of a floating handheld electronic product this work describes the influence of
secondary discharge events during system level ESD testing on the failure threshold of the …