[HTML][HTML] 3D-printing techniques in a medical setting: a systematic literature review

P Tack, J Victor, P Gemmel, L Annemans - Biomedical engineering online, 2016 - Springer
Abstract Background Three-dimensional (3D) printing has numerous applications and has
gained much interest in the medical world. The constantly improving quality of 3D-printing …

Efficacy of patient-specific instruments in total knee arthroplasty: a systematic review and meta-analysis

E Thienpont, PE Schwab, P Fennema - JBJS, 2017 - journals.lww.com
Background: Patient-specific instrumentation (PSI) was introduced with the aim of making
the procedure of total knee arthroplasty more accurate and efficient. The purpose of this …

[HTML][HTML] Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty

S Gong, W Xu, R Wang, Z Wang, B Wang… - Knee Surgery, Sports …, 2019 - Springer
Purpose The purpose of the present study was to compare patient-specific instrumentation
(PSI) with standard instrumentation (SI) in patients undergoing total knee arthroplasty (TKA) …

Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA

W Anderl, L Pauzenberger, R Kölblinger… - Knee Surgery, Sports …, 2016 - Springer
Purpose The aim of this prospective study was to compare early clinical outcome,
radiological limb alignment, and three-dimensional (3D)-component positioning between …

Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis

E Cavaignac, R Pailhe, G Laumond, J Murgier… - International …, 2015 - Springer
Purpose Because published studies on the accuracy achieved with patient-specific guides
during total knee arthroplasty (TKA) contradict each other, this systematic review and meta …

Favourable rotational alignment outcomes in PSI knee arthroplasty: a level 1 systematic review and meta-analysis

A Mannan, TO Smith - The Knee, 2016 - Elsevier
Background Implant malposition in total knee arthroplasty (TKA) often results in
unsatisfactory outcomes. Rotational malalignment leads to impaired patellar tracking …

[HTML][HTML] The mark coventry award: custom cutting guides do not improve total knee arthroplasty clinical outcomes at 2 years followup

D Nam, A Park, JB Stambough, SR Johnson… - … and Related Research®, 2016 - Springer
Abstract Background Custom cutting guides (CCGs; sometimes called patient-specific
instrumentation [PSI]) in total knee arthroplasty (TKA) use preoperative three-dimensional …

Alignment in total knee arthroplasty—A comparison of patient-specific implants with the conventional technique

D Arbab, P Reimann, M Brucker, B Bouillon, C Lüring - The Knee, 2018 - Elsevier
Background Incorrect positioning and malalignment of total knee arthroplasty (TKA)
components can result in implant loosening. Restoration of neutral alignment of the leg is an …

Robotic-assisted total knee arthroplasty improves the outlier of rotational alignment of the tibial prosthesis using 3DCT measurements

T Kaneko, T Igarashi, K Takada, S Yoshizawa… - The Knee, 2021 - Elsevier
Background The aim of the present study was to compare the accuracy of prosthetic
alignment with three-dimensional computed tomography (3DCT) measurements following …

Patient-specific instrumentation in total knee arthroplasty

VJ León-Muñoz, F Martínez-Martínez… - Expert Review of …, 2019 - Taylor & Francis
Introduction: Total knee arthroplasty (TKA) is one of the most commonly performed
orthopedic procedures. During the past decade, patient-specific instrumentation (PSI) has …