[HTML][HTML] 2D–3D reconstruction of distal forearm bone from actual X-ray images of the wrist using convolutional neural networks

R Shiode, M Kabashima, Y Hiasa, K Oka, T Murase… - Scientific Reports, 2021 - nature.com
The purpose of the study was to develop a deep learning network for estimating and
constructing highly accurate 3D bone models directly from actual X-ray images and to verify …

3D–2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch

T De Silva, A Uneri, MD Ketcha… - Physics in Medicine …, 2016 - iopscience.iop.org
In image-guided spine surgery, robust three-dimensional to two-dimensional (3D–2D)
registration of preoperative computed tomography (CT) and intraoperative radiographs can …

AAPM Task Group Report 238: 3D C‐arms with volumetric imaging capability

M Supanich, J Siewerdsen, R Fahrig… - Medical …, 2023 - Wiley Online Library
This report reviews the image acquisition and reconstruction characteristics of C‐arm Cone
Beam Computed Tomography (C‐arm CBCT) systems and provides guidance on quality …

Marker‐free motion correction in weight‐bearing cone‐beam CT of the knee joint

M Berger, K Müller, A Aichert, M Unberath… - Medical …, 2016 - Wiley Online Library
Purpose: To allow for a purely image‐based motion estimation and compensation in weight‐
bearing cone‐beam computed tomography of the knee joint. Methods: Weight‐bearing …

Correction of patient motion in cone-beam CT using 3D–2D registration

S Ouadah, M Jacobson, JW Stayman… - Physics in Medicine …, 2017 - iopscience.iop.org
Cone-beam CT (CBCT) is increasingly common in guidance of interventional procedures,
but can be subject to artifacts arising from patient motion during fairly long (~ 5–60 s) scan …

[HTML][HTML] Realistic C-arm to pCT registration for vertebral localization in spine surgery: A hybrid 3D-2D registration framework for intraoperative vertebral pose …

RR Naik, H Anitha, SN Bhat, N Ampar… - Medical & Biological …, 2022 - Springer
Spine surgeries are vulnerable to wrong-level surgeries and postoperative complications
because of their complex structure. Unavailability of the 3D intraoperative imaging device …

Multi-stage 3D–2D registration for correction of anatomical deformation in image-guided spine surgery

MD Ketcha, T De Silva, A Uneri… - Physics in Medicine …, 2017 - iopscience.iop.org
A multi-stage image-based 3D–2D registration method is presented that maps annotations
in a 3D image (eg point labels annotating individual vertebrae in preoperative CT) to an …

Posterior pelvic tilt from supine to standing in patients with symptomatic developmental dysplasia of the hip

T Tani, M Takao, K Uemura, Y Otake… - Journal of …, 2020 - Wiley Online Library
Pelvic sagittal inclination (PSI) significantly affects the femoral head coverage by the
acetabulum in patients with developmental dysplasia of the hip (DDH), while no reports …

Long-length tomosynthesis and 3D-2D registration for intraoperative assessment of spine instrumentation

X Zhang, A Uneri, P Wu, MD Ketcha… - Physics in Medicine …, 2021 - iopscience.iop.org
Purpose. A system for long-length intraoperative imaging is reported based on longitudinal
motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long …

Change in pelvic sagittal inclination from supine to standing position before hip arthroplasty

K Uemura, M Takao, Y Otake, K Koyama… - The Journal of …, 2017 - Elsevier
Background Cup anteversion and inclination are important for avoiding implant
impingement and dislocation in total hip arthroplasty. However, functional cup anteversion …