Indentation versus tensile measurements of Young's modulus for soft biological tissues
CT McKee, JA Last, P Russell… - Tissue Engineering Part B …, 2011 - liebertpub.com
In this review, we compare the reported values of Young's modulus (YM) obtained from
indentation and tensile deformations of soft biological tissues. When the method of …
indentation and tensile deformations of soft biological tissues. When the method of …
Optical coherence elastography in ophthalmology
Optical coherence elastography (OCE) can provide clinically valuable information based on
local measurements of tissue stiffness. Improved light sources and scanning methods in …
local measurements of tissue stiffness. Improved light sources and scanning methods in …
Cavitation bubble dynamics and microjet atomization near tissue-mimicking materials
In recent years, considerable interest has been devoted to the interactions between
cavitation bubbles and tissue-mimicking materials due to their promising applications in …
cavitation bubbles and tissue-mimicking materials due to their promising applications in …
Mechanical properties of bioengineered corneal stroma
N Formisano, C van der Putten, R Grant… - Advanced …, 2021 - Wiley Online Library
For the majority of patients with severe corneal injury or disease, corneal transplantation is
the only suitable treatment option. Unfortunately, the demand for donor corneas greatly …
the only suitable treatment option. Unfortunately, the demand for donor corneas greatly …
Corneal biomechanical properties in different ocular conditions and new measurement techniques
N Garcia-Porta, P Fernandes, A Queiros… - International …, 2014 - Wiley Online Library
Several refractive and therapeutic treatments as well as several ocular or systemic diseases
might induce changes in the mechanical resistance of the cornea. Furthermore, intraocular …
might induce changes in the mechanical resistance of the cornea. Furthermore, intraocular …
Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls
R Vinciguerra, S Rehman, NA Vallabh… - British Journal of …, 2020 - bjo.bmj.com
Aims To compare the biomechanically corrected intraocular pressure (IOP) estimate (bIOP)
provided by the Corvis-ST with Goldmann applanation tonometry (GAT-IOP) in patients with …
provided by the Corvis-ST with Goldmann applanation tonometry (GAT-IOP) in patients with …
Electrospun GelMA fibers and p (HEMA) matrix composite for corneal tissue engineering
The development of biocompatible and transparent three-dimensional materials is desirable
for corneal tissue engineering. Inspired from the cornea structure, gelatin methacryloyl-poly …
for corneal tissue engineering. Inspired from the cornea structure, gelatin methacryloyl-poly …
[HTML][HTML] In vivo corneal elastography: A topical review of challenges and opportunities
Clinical measurement of corneal biomechanics can aid in the early diagnosis, progression
tracking, and treatment evaluation of ocular diseases. Over the past two decades …
tracking, and treatment evaluation of ocular diseases. Over the past two decades …
Biomechanical impact of the sclera on corneal deformation response to an air-puff: a finite-element study
BA Nguyen, CJ Roberts, MA Reilly - Frontiers in bioengineering and …, 2019 - frontiersin.org
Aim or Purpose: To describe the effect of varying scleral stiffness on the biomechanical
deformation response of the cornea under air-puff loading via a finite-element (FE) model …
deformation response of the cornea under air-puff loading via a finite-element (FE) model …
[HTML][HTML] Comparison of three intraocular pressure measurement methods including biomechanical properties of the cornea
A Smedowski, B Weglarz, D Tarnawska… - … & visual science, 2014 - tvst.arvojournals.org
Purpose.: The aim of this study was to show the usefulness of three methods for measuring
IOP: Goldmann applanation tonometry, rebound tonometry, and Ultra-High-Speed …
IOP: Goldmann applanation tonometry, rebound tonometry, and Ultra-High-Speed …