Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes
PH Charlton, J Mariscal Harana… - American Journal …, 2019 - journals.physiology.org
The arterial pulse wave (PW) is a rich source of information on cardiovascular (CV) health. It
is widely measured by both consumer and clinical devices. However, the physical …
is widely measured by both consumer and clinical devices. However, the physical …
Role of pulse pressure amplification in arterial hypertension: experts' opinion and review of the data
AP Avolio, LM Van Bortel, P Boutouyrie… - …, 2009 - Am Heart Assoc
Arterial hypertension is a major modifiable cardiovascular (CV) risk factor worldwide based
on observational studies of brachial artery blood pressure (BP). In the latest guidelines of the …
on observational studies of brachial artery blood pressure (BP). In the latest guidelines of the …
Establishing reference values for central blood pressure and its amplification in a general healthy population and according to cardiovascular risk factors
Aims Estimated central systolic blood pressure (cSBP) and amplification (Brachial SBP-
cSBP) are non-invasive measures potentially prognostic of cardiovascular (CV) disease. No …
cSBP) are non-invasive measures potentially prognostic of cardiovascular (CV) disease. No …
Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization
JE Sharman, AP Avolio, J Baulmann… - European heart …, 2017 - academic.oup.com
The original Riva-Rocci method to measure blood pressure (BP) using a cuff at the upper
arm assumed the pressure obtained by this technique was a good proxy for central aortic …
arm assumed the pressure obtained by this technique was a good proxy for central aortic …
Measurement, analysis and interpretation of pressure/flow waves in blood vessels
JP Mynard, A Kondiboyina, R Kowalski… - Frontiers in …, 2020 - frontiersin.org
The optimal performance of the cardiovascular system, as well as the break-down of this
performance with disease, both involve complex biomechanical interactions between the …
performance with disease, both involve complex biomechanical interactions between the …
Wave reflection and arterial stiffness in the prediction of 15-year all-cause and cardiovascular mortalities: a community-based study
The value of increased arterial wave reflection, usually assessed by the transit time–
dependent augmentation index and augmented pressure (Pa), in the prediction of …
dependent augmentation index and augmented pressure (Pa), in the prediction of …
Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions–position …
GS Stergiou, G Parati, C Vlachopoulos… - Journal of …, 2016 - journals.lww.com
Office blood pressure measurement has been the basis for hypertension evaluation for
almost a century. However, the evaluation of blood pressure out of the office using …
almost a century. However, the evaluation of blood pressure out of the office using …
Pulse waves
P Salvi - How vascular hemodynamics affects Blood pressure, 2012 - Springer
I am delighted to introduce this new updated edition of Paolo Salvi's volume on Pulse
Waves, brilliantly summarizing the hemodynamics of hypertension and its implications for …
Waves, brilliantly summarizing the hemodynamics of hypertension and its implications for …
Noninvasive estimation of aortic stiffness through different approaches: comparison with intra-aortic recordings
P Salvi, F Scalise, M Rovina, F Moretti, L Salvi… - …, 2019 - Am Heart Assoc
Aortic pulse wave velocity is a worldwide accepted index to evaluate aortic stiffness and can
be assessed noninvasively by several methods. This study sought to determine if commonly …
be assessed noninvasively by several methods. This study sought to determine if commonly …
Arterial pulse wave modeling and analysis for vascular-age studies: a review from VascAgeNet
Arterial pulse waves (PWs) such as blood pressure and photoplethysmogram (PPG) signals
contain a wealth of information on the cardiovascular (CV) system that can be exploited to …
contain a wealth of information on the cardiovascular (CV) system that can be exploited to …