Development of Wireless embedded system using ZigBee protocol to avoid white Gaussian noise and 50 Hz Power line noise in ECG and Pressure Blood signals
K Kalovrektis, T Ganetsos, E Fountas… - 2008 Panhellenic …, 2008 - ieeexplore.ieee.org
Electrocardiogram (ECG) and Pressure blood is a main source for doctors to diagnose the
health condition and pathology of heart. The magnitudes of ECG signals are usually …
health condition and pathology of heart. The magnitudes of ECG signals are usually …
[PDF][PDF] Development of a computerized ECG analysis model using the cubic spline interpolation method
K Kalovrektis, T Ganetsos, N SHAMMAS, I Taylor… - 2011 - researchgate.net
An electrocardiogram (ECG) is a bioelectrical signal which records the heart's electrical
activity versus time. It is an important diagnostic tool for assessing heart functions. The …
activity versus time. It is an important diagnostic tool for assessing heart functions. The …
[PDF][PDF] Development of a novel system to analyse and detect small changes in ECG signals that indicate cardiac disorders
K Kalovrektis, T Ganetsos, N SHAMMAS, I TAYLOR… - 2009 - researchgate.net
The analysis of the electrocardiogram as a diagnostic tool is a relatively old field and it is
therefore often assumed that the ECG is a simple signal that has been fully explored …
therefore often assumed that the ECG is a simple signal that has been fully explored …
[PDF][PDF] In-depth Analysis of Cardiac Signals Using Novel Equipment and Software
An electrocard iogram (ECG) is ab ioelectrical signal wh ich records the heart's electrical
activ ity versus time. It is an important diagnostic tool for assessing heart functions. The …
activ ity versus time. It is an important diagnostic tool for assessing heart functions. The …
[PDF][PDF] Development of a Wireless Embedded System to Reduce the Influence of Gaussian Noise and 50 Hz Power Line Noise in Electromyography(EMG)
K Kalovrektis, T Ganetsos, E Fountas… - … and Computers in …, 2009 - researchgate.net
Electromyography (EMG) is a technique for evaluating and recording the activation signal of
muscles. In EMG, the electrical source is the muscle membrane potential of about-70mV …
muscles. In EMG, the electrical source is the muscle membrane potential of about-70mV …
[PDF][PDF] ΗΚΓ λειτουργία-ανάλυση σήματος με τη χρήση του λογισμικού BioBench.
Γ Τζιτζιλή - 2009 - ir.lib.uth.gr
2.2. 2. ΑΛΛΕΣ ΤΕΧΝΙΚΕΣ ΑΠΕΙΚΟΝΙΣΗΣ 54 2.2. 2.1. Εφαρμογές και ακολουθίες της
μαγνητικής αγγειογραφίας 54 2.2. 2.2. Αγγειογραφία «χρόνου πτήσης»(Time Of Flight MRA) …