Protection of AC microgrid integrated with renewable energy sources–A research review and future trends
The addition of distributed generation to a power system improves its performance. It makes
it more sustainable and efficient. But it also poses substantial challenges for designing a …
it more sustainable and efficient. But it also poses substantial challenges for designing a …
Hierarchical structure and bus voltage control of DC microgrid
Z Shuai, J Fang, F Ning, ZJ Shen - Renewable and Sustainable Energy …, 2018 - Elsevier
Compared to AC microgrids, DC microgrids have the advantage of higher reliability and
efficiency and are convenient to connect with various distribution energy resources (DERs) …
efficiency and are convenient to connect with various distribution energy resources (DERs) …
Transient angle stability of virtual synchronous generators using Lyapunov's direct method
With an increasing number of distributed energy resources integrated into the power system,
inverters need to take on the corresponding responsibility for the security and stability of the …
inverters need to take on the corresponding responsibility for the security and stability of the …
A high-impedance fault detection method for distribution systems based on empirical wavelet transform and differential faulty energy
High-impedance faults (HIFs) pose the greatest challenge for distribution system protection,
especially for microgrids and distribution networks with distributed generators (DGs) that …
especially for microgrids and distribution networks with distributed generators (DGs) that …
Active power oscillation and suppression techniques between two parallel synchronverters during load fluctuations
Z Shuai, W Huang, ZJ Shen, A Luo… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Active power oscillation is observed when two or more parallel synchronverters undergo
load fluctuations, potentially impacting the safe operation of the synchronverters. This article …
load fluctuations, potentially impacting the safe operation of the synchronverters. This article …
Reinforcing fault ride through capability of grid forming voltage source converters using an enhanced voltage control scheme
SF Zarei, H Mokhtari, MA Ghasemi… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
Medium power distributed energy resources (DERs) are commonly connected to medium
voltage distribution systems via voltage source converters (VSCs). Several guidelines and …
voltage distribution systems via voltage source converters (VSCs). Several guidelines and …
Transient stability and current injection design of paralleled current-controlled VSCs and virtual synchronous generators
With development of power electronic technology, the paralleled current-controlled voltage
source converters (CCSs) and virtual synchronous generators (VSGs) system has …
source converters (CCSs) and virtual synchronous generators (VSGs) system has …
Adaptive distance protection for lines connecting converter-interfaced renewable plants
S Paladhi, AK Pradhan - … of Emerging and Selected Topics in …, 2020 - ieeexplore.ieee.org
Fault ride through compliance as imposed by grid codes prevents undesirable
disconnection of renewable plants from the network even during fault. Diversified control …
disconnection of renewable plants from the network even during fault. Diversified control …
Analytical model of inverter-interfaced renewable energy sources for power system protection
Q Liu, K Jia, B Yang, L Zheng… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
The accurate analytical fault analysis model of the emerging inverter-interfaced renewable
energy sources (IIRESs) is an important basis for protection of power system with RESs …
energy sources (IIRESs) is an important basis for protection of power system with RESs …
An adaptive fault ride-through scheme for grid-forming inverters under asymmetrical grid faults
Three-phase four-wire grid-forming (GFM) inverters are promising to interface distributed
energy resources into low-voltage networks. However, these inverters are prone to …
energy resources into low-voltage networks. However, these inverters are prone to …