Ultrawideband de-embedding calibration for magnetic field probes by using symmetric GCPW calibrators
Microstrip line (MS) is commonly used as a calibrator for probe calibration. However, some
issues need to be addressed for high-frequency applications, such as ripple and attenuation …
issues need to be addressed for high-frequency applications, such as ripple and attenuation …
An ultrawideband asymmetric calibration method for a simultaneously electromagnetic near-field probing system
W Shao, H Li, X Tian, B Hou, S Xue… - IEEE Transactions …, 2022 - ieeexplore.ieee.org
Calibration for asymmetry of the simultaneously electromagnetic near-field probing system is
a good way of improving the performance of a two-port probe. The previous rotating …
a good way of improving the performance of a two-port probe. The previous rotating …
Novel calibration method for the asymmetric probing in the near-field measurement with a dual probe
W Shao, Z Yi, X He, W Fang, C Zhou… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Dual probe is capable of simultaneously measuring electric and magnetic fields in the same
position, given that perfectly symmetric design is realized on the transmission paths …
position, given that perfectly symmetric design is realized on the transmission paths …
An ultrawideband four-port composite probe with simultaneous measurement of multicomponent fields and improvement of electric-field suppression
L Wang, X Liu, W Shao, Z Zhu - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
In this study, an ultrawideband four-port composite probe with simultaneous measurement of
multicomponent fields and the improvement of electric-field suppression was developed …
multicomponent fields and the improvement of electric-field suppression was developed …
Electric field probe de-embedding calibration based on through and line standards
The electric field (E-field) probe has been widely used for electromagnetic interference
diagnosis in IEC61967-3. But with the increase in detection frequency, the calibration error …
diagnosis in IEC61967-3. But with the increase in detection frequency, the calibration error …
Design and characterization of a multi-processed differential magnetic field probe by using asymmetric calibration method
W Shao, J Fan, X Tian, S Tang, Z Yi, J Liu… - IEEE Sensors …, 2022 - ieeexplore.ieee.org
In order to improve the spatial resolution of a magnetic near field probe, the design method
combining multiple ports with multiple production processes has been proven effective …
combining multiple ports with multiple production processes has been proven effective …
An asymmetric correction method for differential double-loop magnetic field probing system
W Shao, Y Chen, L Huang… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
Symmetry is a critical assumption and an application barrier in a two-port near-field probing
system before the asymmetric calibration was proposed. Asymmetric calibration can break …
system before the asymmetric calibration was proposed. Asymmetric calibration can break …
Asymmetric calibration and characterization for diff-port magnetic field probing system
Strict symmetry limits the application of the differential port (diff-port) magnetic field probing
system (DMPS). Asymmetric calibration is very meaningful for DMPS. Ultrawindband …
system (DMPS). Asymmetric calibration is very meaningful for DMPS. Ultrawindband …
A virtual network matching method for correcting asymmetric near-field probing system
In symmetric two-port probing system, the measured electromagnetic field signals can be
decoupled. However, in practical application, asymmetric problem is difficult to avoid. So …
decoupled. However, in practical application, asymmetric problem is difficult to avoid. So …
Design and characterisation of a dual probe with double‐loop structure for simultaneous near‐field measurement
Z Yi, Z Chen, X Tian, B Hou, Y Ding… - IET Microwaves …, 2022 - Wiley Online Library
In this study, a near‐field dual probe with a double‐loop structure is designed and
characterised. The high‐performance, low‐loss Rogers material and four‐layer printed …
characterised. The high‐performance, low‐loss Rogers material and four‐layer printed …