A review of microvalves
This review gives a brief overview of microvalves, and focuses on the actuation mechanisms
and their applications. One of the stumbling blocks for successful miniaturization and …
and their applications. One of the stumbling blocks for successful miniaturization and …
Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems
Abstract Polydimethylsiloxane (PDMS Sylgard® 184, Dow Corning Corporation) pre-
polymer was combined with increasing amounts of cross-linker (5.7, 10.0, 14.3, 21.4, and …
polymer was combined with increasing amounts of cross-linker (5.7, 10.0, 14.3, 21.4, and …
[HTML][HTML] New and improved ways to treat hydrocephalus: pursuit of a smart shunt
The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to
supplement or replace lost drainage capacity. Shunts are life-saving devices but are …
supplement or replace lost drainage capacity. Shunts are life-saving devices but are …
Micro-valve using induced-charge electrokinetic motion of Janus particle
Y Daghighi, D Li - Lab on a Chip, 2011 - pubs.rsc.org
A new micro-valve using the electrokinetic motion of a Janus particle is introduced in this
paper. A Janus particle with a conducting hemisphere and a non-conducting hemisphere is …
paper. A Janus particle with a conducting hemisphere and a non-conducting hemisphere is …
Design and Fabrication of a PDMS/Parylene Microvalve for the Treatment of Hydrocephalus
J Oh, G Kim, F Kralick, H Noh - Journal of …, 2011 - ieeexplore.ieee.org
We present a novel microvalve for the treatment of a pathological condition, ie,
hydrocephalus. This microvalve is made of polydimethylsiloxane/Parylene composite layer …
hydrocephalus. This microvalve is made of polydimethylsiloxane/Parylene composite layer …
Microfabricaton of microfluidic check valves using comb-shaped moving plug for suppression of backflow in microchannel
J Hyeon, H So - Biomedical Microdevices, 2019 - Springer
This study reports on an efficient microscale one-way valve system that combines the
physical properties of photopolymerized microstructures and viscoelastic microchannels to …
physical properties of photopolymerized microstructures and viscoelastic microchannels to …
Cerebrospinal fluid volume measurements in hydrocephalic rats
Object Experimental data about the evolution of intracranial volume and pressure in cases of
hydrocephalus are limited due to the lack of available monitoring techniques. In this study …
hydrocephalus are limited due to the lack of available monitoring techniques. In this study …
Hydrodynamic properties of the Certas hydrocephalus shunt
Z Czosnyka, JD Pickard, M Czosnyka - Journal of Neurosurgery …, 2013 - thejns.org
Object Independent testing of hydrocephalus shunts provides information about the quality
of CSF drainage after shunt implantation. Moreover, hydrodynamic parameters of a valve …
of CSF drainage after shunt implantation. Moreover, hydrodynamic parameters of a valve …
PDMS selective bonding for the fabrication of biocompatible all polymer NC microvalves
A Jahanshahi, P Salvo… - Journal of …, 2013 - ieeexplore.ieee.org
Microvalves are commonly used in microfluidic systems to control precisely the liquid flow. In
this paper, the design and fabrication of a normally-closed (NC) all-polymer membrane-type …
this paper, the design and fabrication of a normally-closed (NC) all-polymer membrane-type …
Hydrogel Check-Valves for the Treatment of Hydrocephalic Fluid Retention with Wireless Fully-Passive Sensor for the Intracranial Pressure Measurement
Hydrocephalus (HCP) is a neurological disease resulting from the disruption of the
cerebrospinal fluid (CSF) drainage mechanism in the brain. Reliable draining of CSF is …
cerebrospinal fluid (CSF) drainage mechanism in the brain. Reliable draining of CSF is …