Parameter estimation of distribution lines using SCADA measurements
This article proposes a parameter estimation scheme for three-phase untransposed
distribution lines. The estimation process is carried out using voltage magnitude (rms) and …
distribution lines. The estimation process is carried out using voltage magnitude (rms) and …
Modeling capacitive low-power voltage transformer behavior over temperature and frequency
The use of capacitive dividers (CDs) in medium-voltage (MV) networks started as simple
voltage detectors and as rough voltage measurement instruments for protective purposes …
voltage detectors and as rough voltage measurement instruments for protective purposes …
Impact of uncertainty sources on the voltage control of active distribution grids
Advanced distribution management systems are increasingly required to operate today's
distribution grids and to deal with the challenges brought by both renewable sources and …
distribution grids and to deal with the challenges brought by both renewable sources and …
Modeling stray capacitances of high-voltage capacitive dividers for conventional measurement setups
Stray capacitances (SCs) are a serious issue in high-voltage (HV) applications. Their
presence can alter the circuit or the operation of a device, resulting in wrong or even …
presence can alter the circuit or the operation of a device, resulting in wrong or even …
Метод обґрунтування мінімально припустимого значення ймовірності оцінки результату перевірки параметрів
Y Ryzhov, L Sakovych - Вісник Київського політехнічного інституту …, 2017 - visnykpb.kpi.ua
Анотація У статті запропонований метод обґрунтування мінімально припустимого
значення імовірності оцінки результату перевірки параметрів з врахуванням …
значення імовірності оцінки результату перевірки параметрів з врахуванням …
[PDF][PDF] Minimization measurement requirements for maintenance and repair special communication means
Y Ryzhov, L Sakovych - 2017 - core.ac.uk
In this paper conducted evaluating of the effectiveness of networking IP/MPLS, used as a
base when deploying modern transport networks. The main requirements that apply to the …
base when deploying modern transport networks. The main requirements that apply to the …
The impact of PMU measurement delays and a heterogenous communication network on a linear state estimator
M Asprou, E Kyriakides… - 2016 18th …, 2016 - ieeexplore.ieee.org
The common feature of many monitoring and control applications that will be accommodated
in the future Wide Area Monitoring and Control system will be the quasi real time execution …
in the future Wide Area Monitoring and Control system will be the quasi real time execution …
Bounds of estimated states based on line parameter uncertainties
The accurate monitoring and control of power systems relies heavily on the power system
topology, the accurate models of every component and especially on the accurate …
topology, the accurate models of every component and especially on the accurate …
The effect of PMU measurement delays on a linear state estimator: Centralized Vs decentralized
M Asprou, E Kyriakides - 2017 IEEE Power & Energy Society …, 2017 - ieeexplore.ieee.org
The integration of more GPS-synchronized measurement devices, such as the Phasor
Measurement Unit (PMU), to the transmission level of the power system has set the …
Measurement Unit (PMU), to the transmission level of the power system has set the …
The use of conventional measurements for the identification of bad PMU measurements
M Asprou, C Panayiotou - 13th Mediterranean Conference on …, 2022 - ieeexplore.ieee.org
The maturity of the Synchronized Measurement Technology (SMT) in power systems along
with the realization of the benefits that can be offered by the Phasor Measurement Units …
with the realization of the benefits that can be offered by the Phasor Measurement Units …