Review of grid connection requirements for generation assets in weak power grids
A Etxegarai, P Eguia, E Torres, A Iturregi… - … and Sustainable Energy …, 2015 - Elsevier
The integration of variable energy sources in weak power grids poses many technical and
economic challenges. Both aspects have an impact on the development of grid codes, that is …
economic challenges. Both aspects have an impact on the development of grid codes, that is …
Low‐voltage ride‐through enhancement with the ω and T controls of PMSG in a grid‐integrated wind generation system
SM Tripathi, AN Tiwari, D Singh - IET Generation, Transmission …, 2019 - Wiley Online Library
This study deals with the formulation of a simple control strategy for the enhancement of the
low‐voltage ride‐through (LVRT) capability of the grid‐integrated permanent magnet …
low‐voltage ride‐through (LVRT) capability of the grid‐integrated permanent magnet …
Flexible arrangement of static converters for grid-connected wind energy conversion systems
FB Grigoletto, H Pinheiro - IEEE Transactions on Industrial …, 2013 - ieeexplore.ieee.org
This paper presents a new flexible arrangement of static converters for grid-connected wind
energy conversion systems (WECS). The proposed arrangement uses three-phase voltage …
energy conversion systems (WECS). The proposed arrangement uses three-phase voltage …
[图书][B] Assessment of fault level in power systems with high penetration of non-synchronous generation
RR Aljarrah - 2020 - search.proquest.com
The main goal of this thesis is to develop efficient methods for monitoring the fault level in
the power system with increased penetration of non-synchronous generations (NSGs). This …
the power system with increased penetration of non-synchronous generations (NSGs). This …
Low voltage ride through for a wind turbine based SCAG
K Elyaalaoui, M Ouassaid… - 2015 3rd International …, 2015 - ieeexplore.ieee.org
This paper develops a control strategy for a large wind turbine based on the squirrel cage
asynchronous generator (SCAG). In addition, the transient behavior during Low Voltage …
asynchronous generator (SCAG). In addition, the transient behavior during Low Voltage …
An analytical method for the response of DFIG under voltage dips
Electromagnetic transients resulting from voltage dips complicate the low-voltage ride-
through (LVRT) of doubly fed induction generator (DFIG) based wind turbines (WTs). To …
through (LVRT) of doubly fed induction generator (DFIG) based wind turbines (WTs). To …
[PDF][PDF] Grid Fault Responses of Voltage-Source Converters in Wind Turbine Applications
MG TAUL - 2019 - vbn.aau.dk
Resumé Med et globalt stigende elektrisk energiforbrug samt et ønske om en markant
reduktion i nutidens CO2 aftryk, kræves der nye løsninger i forhold til produktion og …
reduktion i nutidens CO2 aftryk, kræves der nye løsninger i forhold til produktion og …
Power quality issues in small rating wind generation in weak distribution system
In this paper, a wind generator system (WG) comprising of squirrel cage induction
generators (SCIGs) is described and its impact on three-phase four-wire weak distribution …
generators (SCIGs) is described and its impact on three-phase four-wire weak distribution …