Use of a continuous wave laser and pockels cell for sensitive high-resolution collinear resonance ionization spectroscopy
RP De Groote, I Budinčević, J Billowes, ML Bissell… - Physical review …, 2015 - APS
New technical developments have led to a 2 orders of magnitude improvement of the
resolution of the collinear resonance ionization spectroscopy (CRIS) experiment at ISOLDE …
resolution of the collinear resonance ionization spectroscopy (CRIS) experiment at ISOLDE …
Enhanced atomic desorption of 209 and 210 francium from organic coating
S Agustsson, G Bianchi, R Calabrese, L Corradi… - Scientific Reports, 2017 - nature.com
Controlled atomic desorption from organic Poly-DiMethylSiloxane coating is demonstrated
for improving the loading efficiency of 209,210 Fr magneto-optical traps. A three times …
for improving the loading efficiency of 209,210 Fr magneto-optical traps. A three times …
Laser trapping of sodium isotopes for a high-precision β-decay experiment
WL Kruithof - 2012 - research.rug.nl
In 1874 informeerde de 16-jarige Max Planck, die in dat jaar aan een studie natuurkunde
aan de universiteit van Muenchen begon, bij professor Philipp von Jolly naar de …
aan de universiteit van Muenchen begon, bij professor Philipp von Jolly naar de …
Thermal surface neutralization of Fr ions with metal foils for magneto-optical trapping of radioisotopes
H Kawamura, T Aoki, K Harada, T Inoue, S Ito… - arXiv preprint arXiv …, 2019 - arxiv.org
We investigate neutralization processes (especially thermal surface neutralization), which
are required for the magneto-optical trapping of radioactive atoms. A variety of neutralization …
are required for the magneto-optical trapping of radioactive atoms. A variety of neutralization …
[PDF][PDF] Neutralization of Radioactive Francium Atoms Using a Rotatable Yttrium Target
H Kawamura, T Aoki, S Ando, H Arikawa, S Ezure… - 2013 - tohoku.repo.nii.ac.jp
Magneto-optical trapping is one way to precisely measure the properties of francium. A
yttrium target that can neutralize francium ions was developed for the magneto-optical trap …
yttrium target that can neutralize francium ions was developed for the magneto-optical trap …
Development of a collinear laser spectrometer facility at VECC: First test result
MS Ali, A Ray, W Raja, A Bandyopadhyay, V Naik… - Pramana, 2018 - Springer
We report here the development of collinear laser spectroscopy (CLS) system at VECC for
the study of hyperfine spectrum and isotopic shift of stable and unstable isotopes. The facility …
the study of hyperfine spectrum and isotopic shift of stable and unstable isotopes. The facility …