[HTML][HTML] Osseointegration of retrieved 3D-printed, off-the-shelf acetabular implants

L Dall'Ava, H Hothi, J Henckel, A Di Laura… - Bone & joint …, 2021 - boneandjoint.org.uk
Aims The main advantage of 3D-printed, off-the-shelf acetabular implants is the potential to
promote enhanced bony fixation due to their controllable porous structure. In this study we …

[HTML][HTML] A retrieval analysis of the Precice intramedullary limb lengthening system

VC Panagiotopoulou, K Davda, HS Hothi… - Bone & Joint …, 2018 - boneandjoint.org.uk
Objectives The Precice nail is the latest intramedullary lengthening nail with excellent early
outcomes. Implant complications have led to modification of the nail design. The aim of this …

Clinical relevance of corrosion patterns attributed to inflammatory cell‐induced corrosion: A retrieval study

A Di Laura, HS Hothi, JM Meswania… - … Research Part B …, 2017 - Wiley Online Library
In vitro studies have shown that human osteoclasts can corrode stainless steel and titanium
leading to the production of metal ions responsible for inflammatory reactions. Moreover …

[HTML][HTML] Sequelae of large-head metal-on-metal hip arthroplasties: current status and future prospects

CP van Lingen, LM Zagra, HB Ettema… - EFORT Open …, 2016 - eor.bioscientifica.com
Large-head metal-on-metal (MoM) bearings were re-popularised in the late 1990s with the
introduction of modern hip resurfacing (HR), followed closely by large metal head total hip …

Damage analysis of retrieved BioloxⓇ delta components used in hard and soft bearings

J Döring, A Buchholz, M Herbster, J Gehring, U Betke… - Acta Biomaterialia, 2023 - Elsevier
This retrieval study included 43 Biolox delta explants (18 CoC, 25 CoP). Implants were
examined macroscopically, whereby damage was evaluated using a semi quantitative …

Analysis of carbon fiber reinforced PEEK hinge mechanism articulation components in a rotating hinge knee design: a comparison of in vitro and retrieval findings

RA Schierjott, A Giurea, HJ Neuhaus… - BioMed Research …, 2016 - Wiley Online Library
Carbon fiber reinforced poly‐ether‐ether‐ketone (CFR‐PEEK) represents a promising
alternative material for bushings in total knee replacements, after early clinical failures of …

Effect of bearing type on taper material loss in hips from 1 manufacturer

HS Hothi, AP Eskelinen, J Henckel, YM Kwon… - The Journal of …, 2018 - Elsevier
Background Numerous studies have reported on clinical significant volumes of material loss
and corrosion at the head-stem junction of metal-on-metal (MOM) hips; less is understood …

[HTML][HTML] The distribution and severity of corrosion damage at eight distinct zones of metallic femoral stem implants

R Milimonfared, RH Oskouei, M Taylor, LB Solomon - Metals, 2018 - mdpi.com
Metallic taper junctions of modular total hip replacement implants are analysed for corrosion
damage using visual scoring based on different granularity levels that span from analysing …

Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements

H Khatkar, H Hothi, D de Villiers, C Lausmann… - International …, 2017 - Springer
Purpose Ceramic coatings have been used in metal-on-polyethylene (MOP) hips to reduce
the risk of wear and also infection; the clinical efficacy of this remains unclear. This retrieval …

Quantifying material loss from the bearing surfaces of retrieved hip replacements: Method validation

S Bergiers, H Hothi, R Richards, L Dall'Ava… - Tribology …, 2020 - Elsevier
Computational methods used to quantify wear in failed hip arthroplasties are often limited by
human and sampling errors. An automated software solution has been developed to …