Theory of gradient coil design methods for magnetic resonance imaging
SS Hidalgo‐Tobon - Concepts in Magnetic Resonance Part A, 2010 - Wiley Online Library
The process to produce an MR image includes nuclear alignment, RF excitation, spatial
encoding, and image formation. In simple terms, an magnetic resonance imaging (MRI) …
encoding, and image formation. In simple terms, an magnetic resonance imaging (MRI) …
An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging
We describe the design and operation of an open-access, very-low-field, magnetic
resonance imaging (MRI) system for in vivo hyperpolarized 3He imaging of the human …
resonance imaging (MRI) system for in vivo hyperpolarized 3He imaging of the human …
Gas flow measurements by NMR
B Newling - Progress in Nuclear Magnetic Resonance …, 2008 - Elsevier
Nuclear magnetic resonance (NMR) is not a sensitive technique by almost any comparison
with other measurement methods. Even in staggeringly high magnetic fields, the Zeeman …
with other measurement methods. Even in staggeringly high magnetic fields, the Zeeman …
Propane-d6 Heterogeneously Hyperpolarized by Parahydrogen
KV Kovtunov, ML Truong, DA Barskiy… - The Journal of …, 2014 - ACS Publications
Long-lived spin states of hyperpolarized propane-d 6 gas were demonstrated following
pairwise addition of parahydrogen gas to propene-d 6 using heterogeneous parahydrogen …
pairwise addition of parahydrogen gas to propene-d 6 using heterogeneous parahydrogen …
In situ and ex situ low‐field NMR spectroscopy and MRI endowed by SABRE hyperpolarization
Abstract By using 5.75 and 47.5 mT nuclear magnetic resonance (NMR) spectroscopy, up to
105‐fold sensitivity enhancement through signal amplification by reversible exchange …
105‐fold sensitivity enhancement through signal amplification by reversible exchange …
Temperature-Ramped 129Xe Spin-Exchange Optical Pumping
We describe temperature-ramped spin-exchange optical pumping (TR-SEOP) in an
automated high-throughput batch-mode 129Xe hyperpolarizer utilizing three key …
automated high-throughput batch-mode 129Xe hyperpolarizer utilizing three key …
XeUS: A second-generation automated open-source batch-mode clinical-scale hyperpolarizer
JR Birchall, RK Irwin, P Nikolaou, AM Coffey… - Journal of Magnetic …, 2020 - Elsevier
We present a second-generation open-source automated batch-mode 129 Xe
hyperpolarizer (XeUS GEN-2), designed for clinical-scale hyperpolarized (HP) 129 Xe …
hyperpolarizer (XeUS GEN-2), designed for clinical-scale hyperpolarized (HP) 129 Xe …
High-resolution low-field molecular magnetic resonance imaging of hyperpolarized liquids
We demonstrate the feasibility of microscale molecular imaging using hyperpolarized proton
and carbon-13 MRI contrast media and low-field (47.5 mT) preclinical scale (38 mm id) 2D …
and carbon-13 MRI contrast media and low-field (47.5 mT) preclinical scale (38 mm id) 2D …
Low-Cost Purpose-Built Ultra-Low-Field NMR Spectrometer
Low-field NMR has emerged as a new analytical technique for the investigation of molecular
structure and dynamics. Here, we introduce a highly integrated ultralow-frequency NMR …
structure and dynamics. Here, we introduce a highly integrated ultralow-frequency NMR …
[HTML][HTML] Mutual benefit achieved by combining ultralow-field magnetic resonance and hyperpolarizing techniques
K Buckenmaier, M Rudolph, P Fehling… - Review of Scientific …, 2018 - pubs.aip.org
Ultralow-field (ULF) nuclear magnetic resonance spectroscopy (MRS) and magnetic
resonance imaging (MRI) are promising spectroscopy and imaging methods allowing for …
resonance imaging (MRI) are promising spectroscopy and imaging methods allowing for …