Effective dose assessment for patients undergoing contemporary fluoroscopically guided interventional procedures

X Li, JA Hirsch, MM Rehani… - American Journal of …, 2020 - Am Roentgen Ray Soc
OBJECTIVE. The purpose of this study was to establish procedure-specific air kerma-area
product (KAP) and effective dose for a large number of fluoroscopically guided interventional …

Optimization of radiation doses for open lumbar spinal fusion using C-arm fluoroscopy and impact on radiation-induced cancer: a pilot study

C Van Ngoc Ty, I Fitton, R Arvieu, E Ferrero… - European Spine …, 2024 - Springer
Purpose Intraoperative fluoroscopy use is essential during spinal fusion procedures. The
amount of radiation dose should always be minimized. This study aimed to determine the …

Assessment of organ doses, peak skin doses and effective doses in patients undergoing anterior cervical discectomy and fusion utilising VirtualDose-IR software

V Metaxas, C Dimitroukas, F Efthymiou… - Radiation Protection …, 2024 - academic.oup.com
In this study, the effect of patient-and procedure-related parameters on organ doses (ODs),
peak skin dose (PSD) and effective dose (E) during anterior cervical discectomy and fusion …

Optimisation of patient dose and image quality in fluoroscopically guided cervical spine surgery: a phantom-based study

VI Metaxas, GA Messaris, GD Gatzounis… - Radiation protection …, 2019 - academic.oup.com
The purpose of the current study was to provide useful data, which may help neurosurgeons
to manage the patient dose and image quality in spinal surgery procedures, utilising a …

Lumbar discectomy and fusion: Organs' dose and effective dose estimation using Monte Carlo simulation

V Metaxas, F Efthymiou, C Dimitroukas, H Delis… - Applied Radiation and …, 2023 - Elsevier
In this study, the effect of patient-and procedure-related parameters on organs' dose (OD),
peak skin dose (PSD) and effective dose (ED) during lumbar discectomy and fusion (LDF) …

Do the bmi and surgeon influence the patient dose in fluoroscopically guided lumbar discectomy and fusion?

VI Metaxas, GA Messaris, GD Gatzounis… - Radiation Protection …, 2019 - academic.oup.com
A survey was conducted to evaluate the role of the surgeon and the patients' body size, on
patient radiation dose in fluoroscopically guided lumbar discectomy and fusion (LDF) …

Patient size indices and dose in fluoroscopically guided lumbar discectomy and fusion: a preliminary study

VI Metaxas, GD Gatzounis, FN Tzortzidis… - Radiation Protection …, 2020 - academic.oup.com
Patient dose values varied significantly during interventional procedures, mainly due to the
patient size, operators' choices and clinical complexity. In this study, the effect of applying a …

Radiation Exposure and Protection

JR James, TM Martin, Y Liang - Image Guided Interventions of the Spine …, 2021 - Springer
The need for radiation protection in a complex interventional treatment that involves
computed tomography (CT) or fluoroscopy can sometimes be overlooked. Any radiation …

[PDF][PDF] Evaluation of patient dose during fluoroscopically guided cervical spinal fusion

V Metaxas - 2017 - pdfs.semanticscholar.org
In this chapter, the problem, methodological approach and the research studies are outlined.
The present thesis was developed to address a number of radiological protection issues …

[引用][C] Patient radiation dose in percutaneous nephrolithotomy (PCNL)

Γ Καραμούντζου - 2019