Review on fault‐diagnosis and fault‐tolerance for DC–DC converters

GK Kumar, D Elangovan - IET Power Electronics, 2020 - Wiley Online Library
The DC–DC converters operate extensively in a variety of industrial applications such as
electric vehicles, renewable energy systems, aerospace applications, consumer electronics …

Analysis and applications of parasitic capacitance cancellation techniques for EMI suppression

S Wang, FC Lee - IEEE Transactions on Industrial Electronics, 2009 - ieeexplore.ieee.org
This paper reviews and analyzes five parasitic capacitance cancellation methods. Critical
parameters and constraints determining the cancellation frequency ranges are identified …

Leakage current analytical model and application in single-phase transformerless photovoltaic grid-connected inverter

H Xiao, S Xie - IEEE Transactions on Electromagnetic …, 2010 - ieeexplore.ieee.org
Due to the characteristics of low cost and high efficiency, the transformerless photovoltaic
(PV) grid-connected inverters have been popularized in the application of solar electric …

An improved dipole-moment model based on near-field scanning for characterizing near-field coupling and far-field radiation from an IC

Z Yu, JA Mix, S Sajuyigbe… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
In this paper, an improved dipole-moment model for characterizing near-field coupling and
far-field radiation from an IC based on near-field scanning is proposed. An array of electric …

Transparent and electrically tunable electromagnetic wave absorbing metamaterial

Y Liu, J Zhou, Q Chang, J Liu, J Ji, LH Shao - Applied Physics Letters, 2022 - pubs.aip.org
Electromagnetic protection materials are widely used in both military and civilian fields.
However, the limited wave-absorbing band and low transparency of conventional …

Investigation of radiated electromagnetic interference for an isolated high-frequency DC–DC power converter with power cables

Y Zhang, S Wang, Y Chu - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
To analyze the radiated electromagnetic interference generated by isolated power
converters, this paper proposes a technique to develop a general radiation model for the …

Monitoring and diagnosis for the DC–DC converter using the magnetic near field waveform

Y Chen, X Pei, S Nie, Y Kang - IEEE Transactions on Industrial …, 2010 - ieeexplore.ieee.org
A new diagnostic method for the dc-dc converter, which utilizes the magnetic near field as
the diagnostic criterion, is proposed in this paper. The magnetic near field of the converter is …

A phaseless inverse source method (PISM) based on near-field scanning for radiation diagnosis and prediction of PCBs

L Wang, Y Zhang, F Han, J Zhou… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
In this article, we present an efficient phaseless inverse source method (PISM) to reconstruct
equivalent sources on a printed circuit board (PCB) using magnitude-only single-plane near …

Far-field prediction using only magnetic near-field scanning for EMI test

X Gao, J Fan, Y Zhang, H Kajbaf… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
Far-field prediction for electromagnetic interference (EMI) testing is achieved using only
magnetic near-field on a Huygens's surface. The electrical field on the Huygens's surface is …

Radiation diagnosis of PCBs and ICs using array probes and phaseless inverse source method with a joint regularization

L Wang, Y Zhong, L Chen, Z He… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
In this article, we present a new diagnostic technique for printed circuit boards (PCBs) and
integrated circuits (ICs). This technique consists of an array-probe scanning system and the …