Partial discharge diagnosis and remaining useful lifetime in XLPE extruded power cables under DC voltage: a review

M Fikri, Z Abdul-Malek - Electrical Engineering, 2023 - Springer
This paper collects, summarizes, and discusses more than a hundred important works on
various causes, approaches, and advances in the supervision and diagnosis of extruded …

Ageing assessment of XLPE cable insulation by residual antioxidant content

Y Zhang, S Li, J Gao, S Wang, K Wu… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
To improve the efficiency and accuracy of cable ageing assessment, a new method based
on residual antioxidant (AO) content is proposed. Cross-linked polyethylene (XLPE) cable …

Thermal degradation properties of LDPE insulation for new and aged fine wires

Z Wang, R Wei, X Ning, T Xie, J Wang - Journal of Thermal Analysis and …, 2019 - Springer
The thermal behavior of new and aged low-density polyethylene (LDPE) insulations was
investigated using an SDT Q600 thermal analyzer. The activation energy and pyrolysis …

The lifetime prediction and insulation failure mechanism of XLPE for high-voltage cable

G Li, Z Wang, R Lan, Y Wei, Y Nie… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
The performance parameters and service life of the insulation layer of high-voltage cables
are the key to ensure safe cable operation. Through extracting the mechanical parameters of …

Condition Monitoring of Underground Power Cables Via Power-Line Modems and Anomaly Detection

M Yeganejou, T Ryan, M Reshadi… - … on Power Delivery, 2023 - ieeexplore.ieee.org
Underground power cables are a widely-deployed class of assets in electric power
distribution systems. They are robust in adverse weather conditions and are an aesthetically …

Implementation of non-destructive electrical condition monitoring techniques on low-voltage nuclear cables: I. Irradiation aging of EPR/CSPE cables

E Mustafa, RSA Afia, O Nouini, ZÁ Tamus - Energies, 2021 - mdpi.com
In a nuclear power plant environment, low-voltage cables experience different stresses
during their service life which challenge their integrity. A non-destructive and reliable …

Insulation resistance degradation models of extruded power cables under thermal ageing

X Ge, F Fan, MJ Given, BG Stewart - Energies, 2024 - mdpi.com
Insulation resistance (IR) is an essential metric indicating insulation conditions of extruded
power cables. To deliver reliable IR simulation as a reference for practical cable inspection …

Multiscale analysis of naturally weathered high-voltage XLPE cable insulation in two extreme environments

S Tagzirt, D Bouguedad, A Mekhaldi… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Crosslinked polyethylene (XLPE) insulation is widely used in power cables because of its
excellent properties. Due to the remoteness of end users, the energy is generally …

Thermal-oxidative aging effects on the dielectric properties of nuclear cable insulation

X Chi, J Li, M Ji, W Liu, S Li - Materials, 2020 - mdpi.com
In order to satisfy demands of cable insulation for nuclear power, a low-smoke, halogen-free
flame retardant and better cryogenic property insulation was prepared. The effect of thermal …

Implementation of non-destructive condition monitoring techniques on low-voltage nuclear cables: II. Thermal aging of EPR/CSPE cables

E Mustafa, RSA Afia, A Nawaz, O Nouini, ZÁ Tamus - Energies, 2022 - mdpi.com
Determining the aging state of low-voltage nuclear power plant cables using a
nondestructive and reliable condition monitoring technique is highly desirable as the cables …