Partial pole placement with controller optimization
S Datta, D Chakraborty… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
An arbitrary subset (nm) of the (n) closed loop eigenvalues of an n th order continuous time
single input linear time invariant system is to be placed using full state feedback, at pre …
single input linear time invariant system is to be placed using full state feedback, at pre …
Feedback norm minimisation with regional pole placement
S Datta, D Chakraborty - International Journal of Control, 2014 - Taylor & Francis
This article proposes a convex algorithm for minimising an upper bound of the state
feedback gain matrix norm with regional pole placement for linear time-invariant multi-input …
feedback gain matrix norm with regional pole placement for linear time-invariant multi-input …
Continuous-time System Identification: Refined Instrumental Variables and Sampling Assumptions
R González - 2022 - research.tue.nl
Continuous-time system identification deals with the problem of building continuous-time
models of dynamical systems from sampled input and output data. There are two main …
models of dynamical systems from sampled input and output data. There are two main …
Optimal state feedback controller for a nuclear reactor
PD Vaswani, D Chakraborty - IEEE Transactions on Nuclear …, 2019 - ieeexplore.ieee.org
This article considers the design of an optimal state feedback controller for a nuclear reactor.
The model of 700-MWe Indian pressurized heavy water-type reactor is described and is …
The model of 700-MWe Indian pressurized heavy water-type reactor is described and is …
Low order controller with regional pole placement
In this paper we propose a method to find a low order controller for a single input single
output linear continuous time system which guarantees that the closed loop poles are …
output linear continuous time system which guarantees that the closed loop poles are …
Pole-placement for collocated control of flexible structures
M Abdulkareem, M Mahfouf… - International Journal of …, 2016 - World Scientific
Pole assignment is one of the central problems in most control systems designs. In relation
to low-authority active flexible structural systems where robustness is difficult to achieve …
to low-authority active flexible structural systems where robustness is difficult to achieve …
Enforcing stability through ellipsoidal inner approximations in the indirect approach for continuous-time system identification
Recently, a new indirect approach method for continuous-time system identification has
been proposed that provides complete freedom on the number of poles and zeros of the …
been proposed that provides complete freedom on the number of poles and zeros of the …
Minimal state measurements for regional pole placement
S Datta, D Chakraborty - 2013 American Control Conference, 2013 - ieeexplore.ieee.org
The problem of minimizing the number of state measurements (and hence the number of
sensors) required for placing the poles of a linear time invariant single input system with …
sensors) required for placing the poles of a linear time invariant single input system with …
Consistency and efficiency in continuous-time system identification
RA González - 2020 - diva-portal.org
Continuous-time system identification deals with the problem of building continuoustime
models of dynamical systems from sampled input and output data. In this field, there are two …
models of dynamical systems from sampled input and output data. In this field, there are two …
[PDF][PDF] Minimum Order Controller with Regional Pole Placement
S Datta, D Chakraborty, MN Belur - researchgate.net
A method to find a minimum order controller for a single input single output linear continuous
time system is proposed, which guarantees that the closed loop poles are placed within …
time system is proposed, which guarantees that the closed loop poles are placed within …