High surge impedance loading (HSIL) lines: A review identifying opportunities, challenges, and future research needs
M Ghassemi - IEEE Transactions on Power Delivery, 2019 - ieeexplore.ieee.org
Making old new again: next generation of self-reactive power compensation high surge
impedance loading (HSIL) lines engaging transmission expansion planning (TEP) can be a …
impedance loading (HSIL) lines engaging transmission expansion planning (TEP) can be a …
Optimal design of corona ring on HV composite insulator using PSO approach with dynamic population size
B M'hamdi, M Teguar, A Mekhaldi - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
This paper deals with the use of corona ring at the HV end fitting for improving the electric
field and potential distributions and then for minimizing the corona discharges on 230 kV AC …
field and potential distributions and then for minimizing the corona discharges on 230 kV AC …
Optimization of corona ring for 230 kV polymeric insulator based on finite element method and PSO algorithm
JA Diaz-Acevedo, A Escobar… - Electric Power Systems …, 2021 - Elsevier
The electric field distribution is a very important factor in the performance of polymeric
insulators. This distribution varies under different operating conditions. Therefore, there are …
insulators. This distribution varies under different operating conditions. Therefore, there are …
Optimal design of high voltage composite insulators with grading rings in different configurations
MK Hussain, BM Alshadeedi - Electric Power Systems Research, 2023 - Elsevier
Reliability of high voltage composite insulators depends on achieving an optimal electrical
and geometrical design that produces the lowest electric field strength. This paper proposes …
and geometrical design that produces the lowest electric field strength. This paper proposes …
FEM analysis of electric field distribution for polymeric insulator under different configuration of non-uniform pollution
Considering the extensive use of high voltage insulators, the reliable performance of
insulators is challenged by various weather conditions such as pollution. According to recent …
insulators is challenged by various weather conditions such as pollution. According to recent …
Parameters design optimization of 230 kV corona ring based on electric field analysis and response surface methodology
H Terrab, A Kara - Electric Power Systems Research, 2018 - Elsevier
Ageing of composite insulator in field is mainly affected by the corona discharge activity
caused by high electric stress near the end fittings. In order to control the electric field stress …
caused by high electric stress near the end fittings. In order to control the electric field stress …
Optimization of high voltage electrodes for 765 kV bus post insulators
The designing of the high voltage electrodes such as grading rings, corona rings, and bus
conductors for the station bus post insulators at extra and ultra-high voltage levels pays …
conductors for the station bus post insulators at extra and ultra-high voltage levels pays …
Flashover performance test with lightning impulse and simulation analysis of different insulators in a 110 kV double-circuit transmission tower
Y Zhang, L Li, Y Han, Y Ruan, J Yang, H Cai, G Liu… - Energies, 2018 - mdpi.com
The flashover performance of insulators is the foundation of the calculation of precise
lightning protection. The material and structure of an insulator affect its flashover …
lightning protection. The material and structure of an insulator affect its flashover …
Effect of grading ring on ice characteristics and flashover performance of 220 kVcomposite insulators with different shed configurations
L Shu, S Wang, X Jiang, Q Hu, X Yang… - … on Dielectrics and …, 2015 - ieeexplore.ieee.org
The energized icing tests for five kinds of 220 kV composite insulators with and without the
grading ring (GR) at the high voltage (HV) end are performed in the artificial climate …
grading ring (GR) at the high voltage (HV) end are performed in the artificial climate …
Degradation of various polymeric materials in clean and salt fog conditions: measurements of AC flashover voltage and assessment of surface damages
MA Douar, A Beroual, X Souche - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
This paper is aimed at the assessment of the resistance to tracking of insulators made of
several polymers, widely used in electrical industry (medium voltage cable accessories such …
several polymers, widely used in electrical industry (medium voltage cable accessories such …