Non-invasive continuous measurement of haemodynamic parameters—clinical utility

A Bodys-Pełka, M Kusztal, M Boszko… - Journal of clinical …, 2021 - mdpi.com
The evaluation and monitoring of patients' haemodynamic parameters are essential in
everyday clinical practice. The application of continuous, non-invasive measurement …

Patent landscape review of non-invasive medical sensors for continuous monitoring of blood pressure and their validation in critical care practice

O Litvinova, A Bilir, ED Parvanov, J Niebauer… - Frontiers in …, 2023 - frontiersin.org
Objectives Continuous non-invasive monitoring of blood pressure is one of the main factors
in ensuring the safety of the patient's condition in anesthesiology, intensive care, surgery …

Detecting aortic valve stenosis based on the non-invasive blood pressure waveform—a proof of concept study

E Kho, J Schenk, APJ Vlaar, MM Vis, M Wijnberge… - GeroScience, 2024 - Springer
The incidence of aortic valve stenosis (AoS) increases with age, and once diagnosed,
symptomatic severe AoS has a yearly mortality rate of 25%. AoS is diagnosed with …

Continuous non-invasive vs. invasive arterial blood pressure monitoring during neuroradiological procedure: a comparative, prospective, monocentric, observational …

X Chapalain, T Morvan, JC Gentric, A Subileau… - Perioperative …, 2024 - Springer
Background In the perioperative setting, the most accurate way to continuously measure
arterial blood pressure (ABP) is using an arterial catheter. Surrogate methods such as finger …

Feasibility and Accuracy of Noninvasive Continuous Arterial Pressure Monitoring during Transcatheter Atrial Fibrillation Ablation

A Di Cori, M Parollo, F Fiorentini, S Della Volpe… - Journal of Clinical …, 2023 - mdpi.com
Introduction: Transcatheter atrial fibrillation (AF) ablation is still carried out with continuous
invasive radial arterial blood pressure (IBP) monitoring in many centers. Continuous …

Continuous Noninvasive Blood Pressure Measurement With “ClearSight” Compared to Standard Intermittent Blood Pressure Measurement in Patients With Peripheral …

M Wolfskeil, V Bafort, M Besard, A Moerman… - … of Cardiothoracic and …, 2023 - Elsevier
Objectives To investigate the agreement between continuous noninvasive blood pressure
measurement with the ClearSight system (cNIBP-CS) and standard intermittent noninvasive …

Comparison of the ClearSight™ finger cuff monitor versus invasive arterial blood pressure measurement in elective cardiac surgery patients: a prospective …

U Goncin, KK Liu, B Rawlyk, S Dalkilic… - Canadian Journal of …, 2024 - Springer
Purpose To determine the acceptability of the ClearSight™ system (Edwards Lifesciences
Corp., Irvine, CA, USA) for continuous blood pressure monitoring during elective cardiac …

Monitorage non-invasif de la pression artérielle en anesthésie-réanimation: un état de l'art

K Lakhal, JE Dauvergne - Anesthésie & Réanimation, 2022 - Elsevier
Résumé En anesthésie-réanimation, la pression artérielle fait, depuis longtemps, l'objet
d'une attention soutenue au chevet du patient mais aussi d'intenses efforts de recherche. Il …

Chapter Non-Invasive Blood Pressure

K Lakhal, JE Dauvergne - Hemodynamic Monitoring and Fluid …, 2024 - books.google.com
In acute care settings, protracted and/or profound arterial hypotension is associated with a
higher risk of mortality, myocardial ischemia, stroke and acute kidney injury.[1-3] Arterial …

Immediate reduction in left ventricular ejection time following TAVI is associated with improved quality of life

J Schenk, E Kho, S Rellum, J Kromhout… - Frontiers in …, 2022 - frontiersin.org
Background TAVI has shown to result in immediate and sustained hemodynamic alterations
and improvement in health-related quality of life (HRQoL), but previous studies have been …