[HTML][HTML] In vivo dosimetry in external beam photon radiotherapy: Requirements and future directions for research, development, and clinical practice
External beam radiotherapy with photon beams is a highly accurate treatment modality, but
requires extensive quality assurance programs to confirm that radiation therapy will be or …
requires extensive quality assurance programs to confirm that radiation therapy will be or …
Report of AAPM task group 235 radiochromic film dosimetry: an update to TG‐55
A Niroomand‐Rad, ST Chiu‐Tsao, MP Grams… - Medical …, 2020 - Wiley Online Library
The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high
level of achievable accuracy for a wide range of dose values and its suitability under a …
level of achievable accuracy for a wide range of dose values and its suitability under a …
Radiochromic films for the two-dimensional dose distribution assessment
P Casolaro - Applied Sciences, 2021 - mdpi.com
Radiochromic films are mainly used for two-dimensional dose verification in photon,
electron, and proton therapy treatments. Moreover, the radiochromic film types available …
electron, and proton therapy treatments. Moreover, the radiochromic film types available …
Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry
Purpose Small field dosimetry has been an active area of research for over a decade. It is
now known that large dosimetric errors can be introduced if proper detectors or correction …
now known that large dosimetric errors can be introduced if proper detectors or correction …
Innovative photonic sensors for safety and security, Part III: Environment, agriculture and soil monitoring
In order to complete this set of three companion papers, in this last, we focus our attention on
environmental monitoring by taking advantage of photonic technologies. After reporting on …
environmental monitoring by taking advantage of photonic technologies. After reporting on …
Response characterization of EBT‐XD radiochromic films in megavoltage photon and electron beams
EY León‐Marroquín, D Mulrow, A Darafsheh… - Medical …, 2019 - Wiley Online Library
Purpose The purpose of this study was to investigate the beam quality dependence of the
EBT‐XD radiochromic films for megavoltage photon and electron beam irradiations by …
EBT‐XD radiochromic films for megavoltage photon and electron beam irradiations by …
Experimental validation of Monte Carlo dosimetry for therapeutic beta emitters with radiochromic film in a 3D‐printed phantom
B Van, YK Dewaraja, JT Niedbala, G Rosebush… - Medical …, 2023 - Wiley Online Library
Purpose Validation of dosimetry software, such as Monte Carlo (MC) radiation transport
codes used for patient‐specific absorbed dose estimation, is critical prior to their use in …
codes used for patient‐specific absorbed dose estimation, is critical prior to their use in …
Application of a portable colorimeter for reading a radiochromic film for on-site dosimetry
H Yasuda, H Yoshida - Applied Sciences, 2023 - mdpi.com
Featured Application The present study has demonstrated that simple, accurate on-site
dosimetry with a radiochromic film (Gafchromic EBT-XD) can be achieved by using a …
dosimetry with a radiochromic film (Gafchromic EBT-XD) can be achieved by using a …
Evaluation of 3D-printed bolus for radiotherapy using megavoltage X-ray beams
C Zhang, W Lewin, A Cullen, D Thommen… - Radiological Physics and …, 2023 - Springer
A radiotherapy bolus is a tissue-equivalent material placed on the skin to adjust the surface
dose of megavoltage X-ray beams used for treatment. In this study, the dosimetric properties …
dose of megavoltage X-ray beams used for treatment. In this study, the dosimetric properties …
Energy dependence of the Gafchromic EBT4 film: Dose‐response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x‐ray beams
Background EBT4 was newly released for radiotherapy quality assurance to improve the
signal‐to‐noise ratio in radiochromic film dosimetry. It is important to know its dose …
signal‐to‐noise ratio in radiochromic film dosimetry. It is important to know its dose …