The assessment of wind conditions by means of hot wire sensors and a modifed Wheatstone bridge architecture

V Stornelli, G Ferri, A Leoni, L Pantoli - Sensors and Actuators A: Physical, 2017 - Elsevier
In this paper we present a novel complete anemometric electronic system based on an array
of hot wire sensors, provided by Telecontrolli SME, and a suitable heater feedback that …

Temperature compensation of NTC thermistors based anemometer

P Atanasijevic, P Mihailovic - Sensors and Actuators A: Physical, 2019 - Elsevier
Thermal anemometers based on self-heated thermistors with negative temperature
coefficients are a robust, sensitive and low-cost alternative to standard hot-wire …

[图书][B] Coanda effect: flow phenomenon and applications

NA Ahmed - 2019 - taylorfrancis.com
Coanda effect is a complex fluid flow phenomenon enabling the production of vertical take-
off/landing aircraft. Other applications range from helicopters to road vehicles, from flow …

Non-bridge NTC thermistor anemometer with programmable sensitivity

A Jerotić, D Đokić, P Atanasijević… - Flow Measurement and …, 2024 - Elsevier
This paper presents a programmable constant temperature anemometer (CTA) with a
voltage control of the negative temperature coefficient (NTC) thermistor's working …

A controlled-temperature hot-wire anemometer with voltage feedback linearization

LV Araujo, SYC Catunda, CET Dórea… - 2014 IEEE …, 2014 - ieeexplore.ieee.org
This paper proposes a new architecture of a controlled-temperature hot-wire anemometer
using voltage feedback linearization. The voltage feedback linearizes the sensor input …

SPICE-based dynamical model of a NTC thermoresistive sensor for anemometer applications

LV Araujo, SYC Catunda, D Belfort… - 2015 IEEE …, 2015 - ieeexplore.ieee.org
In this paper a new analog behavioral model of a negative temperature coefficient
thermoresistive sensor developed using SPICE for a hot-wire Wheatstone-Bridge Constant …

Constant Temperature Difference Thermoresistive Radiometer with Enhanced Thermal Link

RFA de Assis, SYC Catunda… - 2024 8th International …, 2024 - ieeexplore.ieee.org
The paper discusses and analyzes an improved structure radiometer that operates with a
thermoresistive sensor. The proposal aims to enhance the heat exchange pathway between …

A Thermal Microfluidic Flow Sensor Screen-Printed onto an Ultrathin PMMA Foil

R Ecker, T Mitteramskogler, B Jakoby - 2023 IEEE SENSORS, 2023 - ieeexplore.ieee.org
This paper reports on the devised fabrication procedure and experimental investigation and
characterization of a thermal based flow sensor for microfluidic systems based on polymer …

Output dynamic range of radiometers based on thermoresistive sensors

VM Nascimento, TLVN Silva… - 2014 IEEE …, 2014 - ieeexplore.ieee.org
Thermo-resistive sensors are widely used in metrology and instrumentation systems. In the
case of radiometers used in measurement of solar radiation, the classical architecture uses …

Analysis of the Wheatstone Bridge Radiometer Performance Dependence on the Ambient Temperature

JTD Segundo, ECS Dantas… - 2021 5th …, 2021 - ieeexplore.ieee.org
In this paper it is analysed the performance dependence on the ambient temperature of the
constant temperature Wheatstone Bridge architecture for a radiometer. The parameters …