Time–frequency feature representation using energy concentration: An overview of recent advances

E Sejdić, I Djurović, J Jiang - Digital signal processing, 2009 - Elsevier
Signal processing can be found in many applications and its primary goal is to provide
underlying information on specific problems for the purpose of decision making. Traditional …

Current status and future trends in frequency-response analysis with a transformer in service

E Gomez-Luna, GA Mayor… - … on power delivery, 2013 - ieeexplore.ieee.org
This paper presents the current status and future trends in the application of the frequency-
response analysis (FRA) technique with the transformer in service (online) through …

Improved detection of power transformer winding movement by extending the FRA high frequency range

M Wang, AJ Vandermaar… - IEEE Transactions on …, 2005 - ieeexplore.ieee.org
FRA tests in the frequency range up to 10 MHz were investigated using simulations and
measurements. It was found that the FRA test was more sensitive to changes in the …

A study of the sweep frequency impedance method and its application in the detection of internal winding short circuit faults in power transformers

Y Liu, S Ji, F Yang, Y Cui, L Zhu, Z Rao… - … on Dielectrics and …, 2015 - ieeexplore.ieee.org
Undetected short circuit faults are a significant problem in power transformers and can
eventually develop into catastrophic faults. At present, frequency response analysis (FRA) is …

Application of wavelet analysis to acoustic emission pulses generated by partial discharges

T Boczar, D Zmarzly - IEEE transactions on dielectrics and …, 2004 - ieeexplore.ieee.org
The subject matter of this paper refers to the improvement of the acoustic emission (AE)
method when used for detection, measurement and location of partial discharges (PDs) in …

Ground fault location testing of a noise pattern based approach on an ungrounded DC system

Y Pan, M Steurer, TL Baldwin - 2010 IEEE Industrial and …, 2010 - ieeexplore.ieee.org
Finding the phase to ground faults in ungrounded distribution systems is very difficult and
time consuming. In recent years, the advances in power electronics favor DC distribution …

Wavelet-aided SVM tool for impulse fault identification in transformers

C Koley, P Purkait, S Chakravorti - IEEE Transactions on power …, 2006 - ieeexplore.ieee.org
Accurate diagnosis of faults in transformers can significantly enhance the safety, reliability,
and economics of power systems. In the case of a fault, it has been established that the …

Insulation failure detection in transformer winding using cross-correlation technique with ANN and k-NN regression method during impulse test

M Rahmatian, B Vahidi, AJ Ghanizadeh… - International Journal of …, 2013 - Elsevier
In this paper, two new schemes are proposed for insulation failure detection in power
transformer windings. In the first step, a real high frequency HV transformer winding is …

Winding movement and condition monitoring of power transformers in service

M Wang - 2003 - open.library.ubc.ca
Power transformers are the most expensive pieces of equipment in a power substation. It is
very important to prevent failures and detect problems in a transformer as early as possible …

Mechanical failure classification for spherical roller bearing ofhydraulic injection molding machine using DWT–SVM

G Xian - Expert Systems with Applications, 2010 - Elsevier
This paper presents a combined discrete wavelet transform (DWT) and support vector
machine (SVM) technique for mechanical failure classification of spherical roller bearing …