Seismic collapse probability and life cycle cost assessment of isolated structures subjected to pounding with smart hybrid isolation system using a modified fuzzy …

A Rayegani, G Nouri - Structures, 2022 - Elsevier
The possibility of pounding on isolated structures with surrounding moat walls is one of the
concerns in the design of isolation systems, especially in pulse-type near-field earthquakes …

Optimum design of PID controlled active tuned mass damper via modified harmony search

AE Kayabekir, G Bekdaş, SM Nigdeli, ZW Geem - Applied Sciences, 2020 - mdpi.com
In this study, the music-inspired Harmony Search (HS) algorithm is modified for the
optimization of active tuned mass dampers (ATMDs). The modification of HS includes the …

Semi-active seismic control of an 11-DOF building model with TMD+ MR damper using type-1 and-2 fuzzy algorithms

A Bathaei, SM Zahrai… - Journal of vibration and …, 2018 - journals.sagepub.com
Nowadays, vibration control of structures is considered as a challenging field among
scientists and engineers. Structural damage and financial losses due to recent earthquakes …

A hybrid metaheuristic method for optimization of active tuned mass dampers

AE Kayabekir, SM Nigdeli… - Computer‐Aided Civil and …, 2022 - Wiley Online Library
A metaheuristic‐based tuning methodology for the optimization of active tuned mass
dampers (ATMDs) is presented. The methodology considers both physical parameters of …

Seismic control of high-rise buildings equipped with ATMD including soil-structure interaction effects

M Shahi, MR Sohrabi, S Etedali - Journal of Earthquake and …, 2018 - World Scientific
The seismic behavior of the structures equipped with ATMD is often investigated based on
the rigid base assumption without considering soil-structure interaction (SSI) effects. The SSI …

[PDF][PDF] Seismic control response of structures using an ATMD with fuzzy logic controller and PSO method

H Shariatmadar, HM Razavi - Struct. Eng. Mech, 2014 - academia.edu
This study focuses on the application of an active tuned mass damper (ATMD) for controlling
the seismic response of an 11-story building. The control action is achieved by combination …

Improving semi-active vibration control of an 11-story structure with non-linear behavior and floating fuzzy logic algorithm

A Bathaei, SM Zahrai - Structures, 2022 - Elsevier
In recent years, vibration control of structures subjected to the wind, earthquakes and traffic
loads has been broadly studied. Based on this, different types of dampers and control …

Bidirectional active control of structures with type-2 fuzzy PD and PID

S Paul, W Yu, X Li - International Journal of Systems Science, 2018 - Taylor & Francis
Proportional-derivative and proportional-integral-derivative (PD/PID) controllers are popular
algorithms in structure vibration control. In order to maintain minimum regulation error, the …

Sliding sector–based adaptive controller for seismic control of structures equipped with active tuned mass damper

S Saadatfar, F Emami, M Khatibinia, H Eliasi - Structures, 2023 - Elsevier
Active tuned mass damper (ATMD) as a reliable active device of structural control can
protect structures subjected to earthquake excitations from the severe seismic damages. The …

[图书][B] Zuverlässigkeit, Sicherheit und Nachhaltigkeit adaptiver Tragwerke

A Ostertag - 2021 - elib.uni-stuttgart.de
In dieser Arbeit wird eine Auslegungsmethode für adaptive Tragwerke unter dynamischen
Lasten vorgestellt, die Anforderungen an Zuverlässigkeit und Sicherheit differenziert …