Amperometric nonenzymatic glucose biosensor based on graphite rod electrode modified by Ni-nanoparticle/polypyrrole composite
This study reports non-ezymatic electrocatalytic amperometric glucose biosensor based on
a graphite rod electrode (GRE) modified with biomimetic-composite consisting of Ni …
a graphite rod electrode (GRE) modified with biomimetic-composite consisting of Ni …
Non-enzymatic glucose sensors involving copper: An electrochemical perspective
Non-enzymatic glucose sensors based on the use of copper and its oxides have emerged
as promising candidates to replace enzymatic glucose sensors owing to their stability, ease …
as promising candidates to replace enzymatic glucose sensors owing to their stability, ease …
A molecularly imprinted electrochemical biosensor based on hierarchical Ti2Nb10O29 (TNO) for glucose detection
A novel molecularly imprinted electrochemical biosensor for glucose detection is reported
based on a hierarchical N-rich carbon conductive-coated TNO structure (TNO@ NC). Firstly …
based on a hierarchical N-rich carbon conductive-coated TNO structure (TNO@ NC). Firstly …
Disposable electropolymerized molecularly imprinted electrochemical sensor for determination of breast cancer biomarker CA 15-3 in human serum samples
AEF Oliveira, AC Pereira, LF Ferreira - Talanta, 2023 - Elsevier
Initially, a printed electrode was fabricated in a paper substrate using carbon nanotube ink,
graphite pencil and silver nanoparticle ink. For that the electrode was modified with gold …
graphite pencil and silver nanoparticle ink. For that the electrode was modified with gold …
Nanostructured nickel oxide electrodes for non-enzymatic electrochemical glucose sensing
Nanostructured nickel (Ni) and nickel oxide (NiO) electrodes were fabricated on Ni foils
using the glancing angle deposition (GLAD) technique. Cyclic voltammetry and …
using the glancing angle deposition (GLAD) technique. Cyclic voltammetry and …
Green synthesis of copper oxide nanoparticles using Ficus elastica extract for the electrochemical simultaneous detection of Cd 2+, Pb 2+, and Hg 2+
In this paper, for the first time, we report the use of a new carbon paste electrode based on a
low-cost pencil graphite powder modified with polyaniline (PANI) and green synthesized …
low-cost pencil graphite powder modified with polyaniline (PANI) and green synthesized …
Nickel phthalocyanine-borophene nanocomposite-based electrodes for non-enzymatic electrochemical detection of glucose
As diabetes has become one of the major health problems affecting hundreds of millions of
people worldwide, the development of electrochemical sensors for the detection of glucose …
people worldwide, the development of electrochemical sensors for the detection of glucose …
2D metal azolate framework as nanozyme for amperometric detection of glucose at physiological pH and alkaline medium
The synthesis of Co-based two-dimensional (2D) metal azolate framework nanosheets (MAF-
5-Co II NS) is described using a simple hydrothermal method. The product was isostructural …
5-Co II NS) is described using a simple hydrothermal method. The product was isostructural …
A novel enzyme-free FI-amperometric glucose biosensor at Cu nanoparticles modified graphite pencil electrode
In this work, graphite pencil electrode (GPE) was modified with Cu nanoparticles (CuNPs)
for enzyme-free flow injection (FI) amperometric detection of glucose. To modify electrode …
for enzyme-free flow injection (FI) amperometric detection of glucose. To modify electrode …
Electrodeposited Ni on pencil graphite electrode for glycerol electrooxidation in alkaline media
In this study, we report the electrocatalytic oxidation of glycerol in alkaline solution onto Ni
modified pencil graphite electrodes (Ni/PGEs). Field-emission gun scanning electron …
modified pencil graphite electrodes (Ni/PGEs). Field-emission gun scanning electron …