Analysis of spatial diffusion of ferric ions in PVA-GTA gel dosimeters through magnetic resonance imaging
This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GTA
gel dosimeters. PVA-GTA gel samples, partly exposed with 6 MV X-rays in order to create an …
gel dosimeters. PVA-GTA gel samples, partly exposed with 6 MV X-rays in order to create an …
Characterization of radiochromic poly (vinyl-alcohol)–glutaraldehyde Fricke gels for dosimetry in external x-ray radiation therapy
S Gallo, E Artuso, MG Brambilla… - Journal of Physics D …, 2019 - iopscience.iop.org
Quality assurance procedures required in modern radiotherapy would greatly benefit from
the development of tissue equivalent dosimeters able to render three-dimensional dose …
the development of tissue equivalent dosimeters able to render three-dimensional dose …
Study of the effect of laponite on Fricke xylenol orange gel dosimeter by optical techniques
S Gallo, L Cremonesi, G Gambarini, L Ianni… - Sensors and Actuators B …, 2018 - Elsevier
Optical absorbance and dynamic light scattering studies of Fricke xylenol orange gel
dosimeters loaded with laponite were carried out with the aim to investigate possible effects …
dosimeters loaded with laponite were carried out with the aim to investigate possible effects …
Assessment of dosimetric sensitivity enhancement of xylenol orange Fricke gel by AuNPs: optical and MR imaging investigation
IS Lima, MA Silveira, J Pavoni, JE Guidelli… - Physics in Medicine …, 2023 - iopscience.iop.org
Metallic nanoparticles, such as gold (Au, Z= 79) and silver (Ag, Z= 47) nanoparticles (AuNPs
and AgNPs, respectively), possess strong surface plasmonic resonance (SPR) and high …
and AgNPs, respectively), possess strong surface plasmonic resonance (SPR) and high …
An investigation into the dose rate and photon energy dependence of the GENA gel dosimeter in the MeV range
Purpose In the current study, the energy and dose rate dependence of a new genipin-based
gel dosimeter, named GENA gel dosimeter, were investigated. Methods Prepared gel …
gel dosimeter, named GENA gel dosimeter, were investigated. Methods Prepared gel …
Parameter estimation and mathematical modeling of the diffusion process of a benzoic acid infused Fricke gel dosimeter
J Vedelago, A Quiroga, S Triviño, F Mattea… - Applied Radiation and …, 2019 - Elsevier
This work presents a mathematical model implementation for studying the diffusion process
of ferric ions in post-irradiated Fricke gel dosimeters. Fricke gel samples were manufactured …
of ferric ions in post-irradiated Fricke gel dosimeters. Fricke gel samples were manufactured …
Measuring output factors and beam profiles formed by multileaf collimators using Fricke gel dosimeter
LN de Oliveira, A de Almeida, LVE Caldas - Physica Medica, 2014 - Elsevier
The accuracy and precision are necessary factors in radiotherapy, especially for
measurements involving output factors and beam profiles; in this case multileaf collimators …
measurements involving output factors and beam profiles; in this case multileaf collimators …
Lithium diborate glass for high-dose dosimetry using the UV-Vis and FTIR spectrophotometry techniques
Glass has been used in radiation dosimetry mainly for its linear response with absorbed
dose, low cost and easy evaluation. The lithium diborate glasses were irradiated with doses …
dose, low cost and easy evaluation. The lithium diborate glasses were irradiated with doses …
Evaluation of high-linearity bone radiation detectors exposed to gamma-rays via FTIR measurements
LN de Oliveira, EO do Nascimento, PAM Júnior… - Applied Radiation and …, 2021 - Elsevier
In radiation physics, the study of new alternative dosimeters is of interest to the growing
branch of dosimetric characterization for radiotherapy applications. The goal of this work …
branch of dosimetric characterization for radiotherapy applications. The goal of this work …