Long-term safety and efficacy of pipeline embolization device in anterior and posterior circulation aneurysms: a systematic review and meta-analysis

E Greco, AKA Ghaith, J Rios-Zermeno, M Ghanem… - World Neurosurgery, 2024 - Elsevier
Background Flow diversion using the Pipeline Embolization Device (PED) has been a
paradigm shift for anterior circulation (AC) aneurysms. However, only a few studies report …

Safety and efficacy profile of off-label use of the Pipeline Embolization Device: A systematic review and meta-analysis

YC Senol, A Orscelik, C Bilgin, H Kobbeisi… - Journal of Stroke and …, 2024 - Elsevier
Objective The off-label utilization of the Pipeline Embolization Device (PED) is a common
practice in numerous medical centers globally. Therefore, we conducted a systematic review …

Flow diversion for posterior circulation aneurysms: a multicenter retrospective study

P Qi, X Tong, X Liang, X Xue, Z Wu… - Therapeutic …, 2023 - journals.sagepub.com
Background: The prevalence of intracranial aneurysms is approximately 3% worldwide.
Posterior circulation (PC) aneurysms have a higher risk of treatment complications than …

Endovascular treatment of large or giant basilar artery aneurysms using the pipeline embolization device: complications and outcomes

H Ge, X Chen, K Liu, Y Zhao, L Zhang, P Liu… - Frontiers in …, 2022 - frontiersin.org
Background This study aimed to investigate clinical and angiographic outcomes of Pipeline
embolization device (PED) treatment of large or giant basilar artery (BA) aneurysms and …

The Pipeline Embolization Device: a decade of lessons learned in the treatment of posterior circulation aneurysms in a multicenter cohort

AA Dmytriw, M Dibas, N Adeeb, MM Salem… - Journal of …, 2022 - thejns.org
OBJECTIVE The Pipeline Embolization Device (PED) has prompted a paradigm shift in the
approach to posterior circulation aneurysms. The year 2021 marks a decade since FDA …

Periprocedural cerebrovascular complications and 30-day outcomes of endovascular treatment for intracranial vertebral artery dissecting aneurysms

J Han, F Liu, J Chen, X Tong, M Han, F Peng… - Journal of …, 2022 - thejns.org
OBJECTIVE The authors undertook an evaluation of periprocedural cerebrovascular
complications and 30-day outcomes of endovascular treatment for intracranial vertebral …

Use of flow diverter device in basilar artery for aneurysm treatment: case series and literature review

C Wang, D Zhu, X Xu, Y Zhou, R Zhao, Q Li… - Frontiers in …, 2022 - frontiersin.org
Background Flow diverters (FDs) for the treatment of basilar artery (BA) aneurysms remain
controversial. In this study, we report our initial experience of flow diversion for treatment of …

Pipeline embolization of complex, wide-necked middle cerebral artery bifurcation aneurysms: a single-center experience

J Wang, X Deng, D Li, Z Yang… - Interventional …, 2024 - journals.sagepub.com
Purpose To evaluate the performance of Pipeline Embolization Device (PED) in complex,
wide-necked middle cerebral artery (MCA) bifurcation aneurysms. Methods We performed a …

Pipeline embolization device for small and medium vertebral artery aneurysms: a multicenter study

H Zhang, H Zhang, J Liu, D Song, Y Zhao, S Guan… - …, 2023 - journals.lww.com
BACKGROUND: Pipeline embolization devices (PEDs) have been increasingly used for the
treatment of posterior circulation aneurysms. OBJECTIVE: To investigate the safety and …

Comparison of clinical and histopathological characteristics of short-term progressive and non-progressive blood blister-like aneurysms

D Wen, R Chen, NW Kieran, M Sharifian-Dorche… - Acta …, 2021 - Springer
Background Many blood blister aneurysms (BBAs) have been documented with a rapid
progression history in repeated angiography. The underlying mechanism and clinical …