JCS/JHRS 2019 guideline on non-pharmacotherapy of cardiac arrhythmias

A Nogami, T Kurita, H Abe, K Ando, T Ishikawa… - Circulation …, 2021 - jstage.jst.go.jp
Pacemaker treatment for bradyarrhythmia was first approved for national health insurance
coverage in Japan in 1974, and its use rapidly became widespread thereafter …

[HTML][HTML] Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation

A Aryana, G Mugnai, SM Singh, DK Pujara… - Heart Rhythm, 2016 - Elsevier
background Limited data exist on procedural and biophysical indicators of pulmonary vein
(PV) isolation durability after the cryoballoon ablation of atrial fibrillation (AF). Objective The …

Oneyear followup after single procedure cryoballoon ablation: a comparison between the first and second generation balloon

GDI Giovanni, K Wauters… - Journal of …, 2014 - Wiley Online Library
A Comparison Between the First and Second Generation Balloon Background With respect
to the first generation Cryoballoon (CB), the second generation (Cryoballoon Advance [CB …

Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up

GB Chierchia, G Di Giovanni, G Ciconte… - Europace, 2014 - academic.oup.com
Abstract Background The novel cryoballoon Advance (CB-A) has proven to achieve
significantly lower temperatures and faster pulmonary vein isolation (PVI) times in …

Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second …

G Ciconte, G Baltogiannis, C de Asmundis… - Ep …, 2015 - academic.oup.com
Aims To assess the 1 year efficacy of pulmonary vein isolation (PVI) as index procedure for
persistent atrial fibrillation (PersAF) comparing conventional radiofrequency irrigated-tip …

Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoon

G Ciconte, L Ottaviano, C De Asmundis, G Baltogiannis… - Heart Rhythm, 2015 - Elsevier
Background No data are available about the clinical outcome of pulmonary vein isolation
(PVI) as an index procedure for persistent atrial fibrillation (PersAF) ablation using the …

[HTML][HTML] Catheter ablation using the third-generation cryoballoon provides an enhanced ability to assess time to pulmonary vein isolation facilitating the ablation …

A Aryana, M Kowalski, PG O'Neill, CH Koo, HW Lim… - Heart Rhythm, 2016 - Elsevier
Background Limited data exist on cryoablation of atrial fibrillation (Cryo-AF) using the newly
available third-generation (Arctic Front Advance-Short Tip [AFA-ST]) cryoballoon. Objective …

Recent advances in cryoballoon ablation for atrial fibrillation

TG Osorio, HE Coutino, P Brugada… - Expert review of …, 2019 - Taylor & Francis
Introduction: Pulmonary vein isolation (PVI), by catheter ablation, represents the current
treatment for drug-resistant atrial fibrillation (AF). Nowadays cryoballoon (CB) is a …

Comparison of the first and second cryoballoon: high-volume single-center safety and efficacy analysis

F Straube, U Dorwarth, M Schmidt… - Circulation …, 2014 - Am Heart Assoc
Background—Cryoballoon (CB) ablation results in> 70% freedom from atrial fibrillation at 1
year. Single-center data of the first (CBG1) and second (CBG2) cryoballoon, recently …

Initial experience of three-minute freeze cycles using the second-generation cryoballoon ablation: acute and short-term procedural outcomes

GB Chierchia, G Di Giovanni, J Sieira-Moret… - Journal of Interventional …, 2014 - Springer
Background The second-generation cryoballoon (CB-A)(Arctic Front Advance, Cryocath,
Medtronic, MN, USA) might significantly improve procedural outcome with respect to the first …