Evaluation of fatigue behavior in dental implants from in vitro clinical tests: a systematic review

R Rojo, M Prados-Privado, AJ Reinoso… - Metals, 2018 - mdpi.com
In the area of dentistry, there is a wide variety of designs of dental implant and materials,
especially titanium, which aims to avoid failures and increase their clinical durability. The …

Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values

D Xia, H Lin, S Yuan, W Bai… - Bio-Medical Materials …, 2014 - content.iospress.com
Implant-abutment assemblies are usually subject to long-term cyclic loading. To evaluate the
dynamic fatigue performance of implant-abutment assemblies with different tightening …

The mechanical behavior of a screwless Morse taper implant–abutment connection: an in vitro study

A Bagegni, V Weihrauch, K Vach, R Kohal - Materials, 2022 - mdpi.com
The use of screwless Morse taper implant–abutment connections (IAC) might facilitate the
clinician's work by eliminating the mechanical complications associated with the retention …

In vitro analysis of prosthetic abutment and angulable frictional implant interface adaptation: Mechanical and microbiological study

RAV Júnior, LC Aranha, CN Elias, EF Martinez - Journal of Biomechanics, 2021 - Elsevier
The aim of this study was to evaluate, in vitro, the microbiological sealing at the implant and
different angles frictional prosthetic abutment interface, submitted or not to mechanical …

Influence of abutment angulation on loss of prosthetic abutment torque under mechanical cycling

D Hein, JC Joly, MH Napimoga, DC Peruzzo… - The Journal of Prosthetic …, 2021 - Elsevier
Statement of problem Internal conical connections provide mechanical stability for the
prosthetic abutment and implant connection. However, some clinical situations require the …

[PDF][PDF] Effect of the Coronal Wall Thickness of Dental Implants on the Screw Joint Stability in the Internal Implant-Abutment Connection.

JH Lee, YH Huh, CJ Park, LR Cho - International Journal of Oral & …, 2016 - researchgate.net
Purpose: To evaluate the effect of implant coronal wall thickness on load-bearing capacity
and screw joint stability. Materials and Methods: Experimental implants were customized …

[HTML][HTML] Retrieval of a fractured implant abutment using a modified cover screw removal instrument: A clinical report

W Zhang, L Wang, F Yang - The Journal of Prosthetic Dentistry, 2023 - Elsevier
Implant abutment fractures are an uncommon mechanical complication, and the removal of
the abutment fragment and replacement with a new prosthesis is the best solution. However …

Micromotion of implant-abutment interfaces (IAI) after loading: correlation of finite element analysis with in vitro performances

Z Li, S Gao, H Chen, R Ma, T Wu, H Yu - Medical & Biological Engineering …, 2019 - Springer
Micromotion between IAI affects long-term survival rate of dental implants. The use of
practical implants for mechanical test is costly. Finite element analysis (FEA) could test the …

Effect of internal hexagonal index on removal torque and tensile removal force of different Morse taper connection abutments

TS de Oliveira Silva, SMM Alencar… - The Journal of Prosthetic …, 2017 - Elsevier
Statement of problem The maintenance of the mechanical stability of implant-abutment
connections is relevant to the clinical success of implant-supported restorations. However …

Influence of abutment design on stress distribution in narrow implants with marginal bone loss: a finite element analysis

S Yenigün, P Ercal, E Özden Yenigün, AB Katipoğlu - 2021 - acikerisim.atlas.edu.tr
Purpose: The aim of this study was to determine the effect of solid (one-piece) and two-piece
abutments on the stress profile of narrow implants with marginal bone loss. Materials and …