[HTML][HTML] Photoneutron production mechanisms, their characteristics, and shielding strategies in high-energy linac environment: A review
Radiotherapy, a mainstay cancer treatment for patients worldwide, utilizes medical linear
accelerators (linacs) with photon energies ranging from 4 MV to 25 MV. However, concerns …
accelerators (linacs) with photon energies ranging from 4 MV to 25 MV. However, concerns …
The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator
L Montgomery, M Evans, L Liang, R Maglieri… - Medical …, 2018 - Wiley Online Library
Purpose Neutrons are an unavoidable by‐product of high‐energy radiation therapy
treatments that deliver unwanted nontarget dose to patients. Use of flattening‐filter‐free …
treatments that deliver unwanted nontarget dose to patients. Use of flattening‐filter‐free …
Comparison of Flattening Filter (FF) and Flattening-Filter-Free (FFF) 6 MV photon beam characteristics for small field dosimetry using EGSnrc Monte Carlo code
S Sangeetha, CS Sureka - Radiation Physics and Chemistry, 2017 - Elsevier
The present study is focused to compare the characteristics of Varian Clinac 600 C/D
flattened and unflattened 6 MV photon beams for small field dosimetry using EGSnrc Monte …
flattened and unflattened 6 MV photon beams for small field dosimetry using EGSnrc Monte …
Feasibility of flattening filter free beams for hippocampal avoidance whole-brain radiotherapy: a dosimetric and radiobiological analysis
F Liu, Y Peng, Q Li, Q Zhang, H Shi, S Qie… - Frontiers in …, 2023 - frontiersin.org
Objectives The purpose of this study is to evaluate the potential of the flattening filter free
(FFF) mode of a linear accelerator for patients with hippocampal avoidance whole-brain …
(FFF) mode of a linear accelerator for patients with hippocampal avoidance whole-brain …
[PDF][PDF] Investigation of LINAC structural effects on photoneutron specified parameters using FLUKA code
M Ashrafinia, A Hadadi, D Sardari… - Iranian Journal of …, 2020 - researchgate.net
Results: Photoneutron spectrum analysis indicated that neutrons with highest relative
biological effectiveness were delivered to the phantom surface, and opening the field from …
biological effectiveness were delivered to the phantom surface, and opening the field from …
Evaluation of the linac neutron dose profile for various depths and field sizes: a Monte Carlo study
DNY Prasada, N Ciamaudi, M Fadli… - Biomedical Physics …, 2021 - iopscience.iop.org
High-energy medical linear accelerator (Linac) has been widely used for treating cancer
patients. However, with its effectiveness, high-energy linac yields an undesirable amount of …
patients. However, with its effectiveness, high-energy linac yields an undesirable amount of …
A study of flattening filter removal effect of 15 MV linac on photoneutron dose
N Mohammadi - Journal of Radiation Safety and Measurement, 2023 - rsm.kashanu.ac.ir
In accelerators operating energies above 7 MV, photoneutrons are produced by the
interaction of photonuclear interaction with the heavy metals that constructed the linear …
interaction of photonuclear interaction with the heavy metals that constructed the linear …
Monte Carlo modelling of peripheral dose and risk of secondary malignancy in flattening-filter-free and 10 MV photon beams for paediatric radiotherapy
Y Ben Bouchta - 2019 - open.library.ubc.ca
One of the most serious late side effects of cancer treatments is the development of a second
malignant neoplasm (SMN). While the risk of SMN is influenced by many factors, radiation …
malignant neoplasm (SMN). While the risk of SMN is influenced by many factors, radiation …
دز غیرمنتظره و اثر بیولوژیکی ناشی از آلودگی نوترونی در شتابدهندههای خطی
حدادی, سرداری, سعیدزاده - سنجش و ایمنی پرتو, 2018 - rsm.kashanu.ac.ir
فوتون پرانرژی موجب تولید آلودگی نوترونی در شتابدهندههای خطی پزشکی میشوند. اثر
بیولوژیکی نسبی نوترون ۲۰ برابر فوتون است، بنابراین آسیب آن در بافت بیولوژیکی …
بیولوژیکی نسبی نوترون ۲۰ برابر فوتون است، بنابراین آسیب آن در بافت بیولوژیکی …
Unexpected dose and the biological effect of neutron contamination in linear accelerators
A Hadadi, D Sardari… - Journal of Radiation Safety …, 2018 - rsm.kashanu.ac.ir
Employing High-energy photons in medical linear accelerators can lead to neutron
contamination. The relative biological effect of neutrons is 20 times higher than photons …
contamination. The relative biological effect of neutrons is 20 times higher than photons …