The membrane shape mapping of the artificial ventricle in the actual dimensions

W Sulej, K Murawski - 2017 Federated Conference on …, 2017 - ieeexplore.ieee.org
The paper sets out and presents a new approach to determine the shape of the flaccid
membrane of the extracorporeal pneumatic heart assist pump. This is a continuation of …

Determining the stroke volume of the artificial ventricle using the numerical integration method

W Sulej, K Murawski - 2017 Signal Processing: Algorithms …, 2017 - ieeexplore.ieee.org
This paper sets out and presents a new approach to determine the stroke volume of the
artificial ventricle. The stroke volume of the chamber is one of the basic heart function …

Optical distortion compensation in the visual measurement with the new Depth From Defocus method

W Sulej, K Murawski, T Pustelny - Photonics Letters of Poland, 2017 - photonics.pl
The paper presents new approach to compensation the inaccuracy of shape mapping of the
flaccid membrane used in the extracorporeal pneumatic heart assist pump. The original …

Optimizing the light source design for a sensor to measure the stroke volume of the artificial heart

K Murawski, M Murawska… - 13th Conference on …, 2018 - spiedigitallibrary.org
The article presents the results of optimizing an illuminator structure, which is an integral part
of the optical sensor, for determining the stroke volume and cardiac output of the …

Study of the influence of a light source on the result of the reconstruction of the flaccid membrane of an artificial heart

K Murawski, W Sulej - 2018 Federated Conference on …, 2018 - ieeexplore.ieee.org
The article presents the influence of the used light sources (illuminators) on the result of the
3D reconstruction of the flaccid membrane surface shape. The research was carried out …

New approach to accuracy measurement of the membrane shape mapping of the heart assist pump

W Sulej, K Murawski - … Conference on Methods & Models in …, 2018 - ieeexplore.ieee.org
This paper sets out a new approach to measuring the accuracy of the membrane shape
mapping of the pulse-type heart assist pump. In the studies, the authors' method for …

Model-based measurement of the stroke volume of a VAD in close-to-real conditions

W Sulej, K Murawski, T Pustelny - 13th Conference on …, 2018 - spiedigitallibrary.org
The presented research concerns the determination of the pulse discharge volume of an
extracorporeal pneumatic heart assist pump. The publication proposes a method for …

Visual measurement of any shape of the flaccid membrane of the extracorporeal pneumatic heart assist pump

W Sulej, K Murawski - Optics, Photonics, and Digital …, 2018 - spiedigitallibrary.org
The new visual method has been invented in order to measure the stroke volume of the
extracorporeal pneumatic heart assist pump. Heart pumps of this type have a pneumatic …

Application of 3D printed models to visual measurement in the new innovative depth from defocus method

W Sulej, K Murawski - 3D Printed Optics and Additive Photonic …, 2018 - spiedigitallibrary.org
The new innovative Depth from Defocus (DFD) method was used to visual measurement of
the stroke volume of the extracorporeal pneumatic heart assist pump. The heart pump …

Studying the influence of markers arrangement on accuracy of the membrane shape mapping in the new DFD method

W Sulej - 13th Conference on Integrated Optics: Sensors …, 2018 - spiedigitallibrary.org
The Depth from Defocus (DFD) type method was developed for visual distance
measurement. It was used to determine the shape of the flaccid membrane of the …