The response of CR-39 nuclear track detector to 1–9 MeV protons
The response of CR-39 nuclear track detector (TasTrak®) to protons in the energy range of
0.92–9.28 MeV has been studied. Previous studies of the CR-39 response to protons have …
0.92–9.28 MeV has been studied. Previous studies of the CR-39 response to protons have …
Research with plasma foci in countries of Asia, Africa, and Latin America
AE Dubinov, EI Fomicheva, LA Senilov - Reviews of Modern Plasma …, 2020 - Springer
This paper considers the modern level of technique, research, and application of “plasma
focus” facilities in the countries of Asia, Africa, and Latin America. A description of the …
focus” facilities in the countries of Asia, Africa, and Latin America. A description of the …
Small plasma focus studied as a source of hard X-ray
F Castillo-Mejía, MM Milanese… - IEEE transactions on …, 2001 - ieeexplore.ieee.org
An experimental study on hard X-ray pulses emitted by a small plasma focus is performed,
regarding its application to biological radiographs in fast dynamic situations. It is found that …
regarding its application to biological radiographs in fast dynamic situations. It is found that …
Scope of plasma focus with argon as a soft X-ray source
M Zakaullah, K Alamgir, M Shafiq… - IEEE transactions on …, 2002 - ieeexplore.ieee.org
The X-radiation emission from a low energy plasma focus with argon as a filling gas is
investigated. Specifically, the attention is paid to determine the system efficiency for argon K …
investigated. Specifically, the attention is paid to determine the system efficiency for argon K …
Comparative study of soft x-ray emission characteristics in a low energy dense plasma focus device
An investigation on the soft x rays emitted in a 2.2 kJ Mather-type dense plasma focus
device using a multichannel diode spectrometer and a simple pinhole camera is reported …
device using a multichannel diode spectrometer and a simple pinhole camera is reported …
Imaging of fusion reaction zone in plasma focus
M Zakaullah, I Akhtar, G Murtaza, A Waheed - Physics of Plasmas, 1999 - pubs.aip.org
In a low energy (2.3 kJ) Mather-type deuterium plasma focus, neutron and charged particle
emission is investigated by using time-resolved neutron detectors and time-integrated …
emission is investigated by using time-resolved neutron detectors and time-integrated …
Neutron anisotropy and X-ray production of the FN-II dense plasma focus device
F Castillo, JJE Herrera, J Rangel, A Alfaro… - Brazilian Journal of …, 2002 - SciELO Brasil
The FN-II Dense Plasma Focus is a small (< 5kJ) Mather type device, where the
dependence of neutron yield and its anisotropy, in terms of deuterium filling pressure, and …
dependence of neutron yield and its anisotropy, in terms of deuterium filling pressure, and …
Low-energy plasma focus as a tailored X-ray source
Abstract A low-energy (2.3 kJ) plasma focus energized by a single 32-μF capacitor charged
at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source …
at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source …
Plasma focus as a high intensity flash X-ray source for biological radiography
A study on X-ray emission from a low energy (3.3 kJ) plasma focus (PF) device operated
with hydrogen is reported. X-ray are detected by using an X-ray detector consisting of three …
with hydrogen is reported. X-ray are detected by using an X-ray detector consisting of three …
Enhanced copper K-alpha radiation from a low-energy plasma focus
M Zakaullah, K Alamgir, M Shafiq, SM Hassan… - Applied Physics …, 2001 - pubs.aip.org
A low-energy (2.3 kJ) plasma focus is operated in an enhanced Cu Kα line emission mode.
The emission is dominated by the interaction of electrons in the current sheath with the …
The emission is dominated by the interaction of electrons in the current sheath with the …