Frequency-adjustable positive sequence detector for power conditioning applications
MS Pádua, SM Deckmann… - 2005 IEEE 36th Power …, 2005 - ieeexplore.ieee.org
This paper proposes a novel and simple positive sequence detector (PSD), which is
inherently self-adjustable to fundamental frequency deviations by means of a software …
inherently self-adjustable to fundamental frequency deviations by means of a software …
Smart grid initiative
R Carnieletto, DI Brandao, FA Farret… - IEEE Industry …, 2011 - ieeexplore.ieee.org
The Primary Goal of this article is to discuss the development of intelligent controls for a
power electronic inverter capable of interfacing a photovoltaic (PV)-based unit to the utility …
power electronic inverter capable of interfacing a photovoltaic (PV)-based unit to the utility …
Synchronisation method for three-phase PWM converters under unbalanced and distorted grid
RF De Camargo, H Pinheiro - IEE Proceedings-Electric Power Applications, 2006 - IET
A new open-loop synchronisation method for three-phase PWM converters connected to the
utility grid is proposed, which gives good performance under distorted and highly …
utility grid is proposed, which gives good performance under distorted and highly …
[PDF][PDF] Análise e controle da energia elétrica através de técnicas de processamento digital de sinais
FP Marafão - … de Campinas-UNICAMP, Campinas, Tese de …, 2004 - repositorio.unicamp.br
Este trabalho apresenta uma Metodologia Seletiva de Identificaçao das parcelas
consideradas ideais de tensao e corrente elétricas em um sistema polifásico, bem como das …
consideradas ideais de tensao e corrente elétricas em um sistema polifásico, bem como das …
Single and three phase moving average filter PLLs: Digital controller design recipe
This work proposes a simple and easy to use design recipe for the proportional–integral
digital controller of a Phase Locked Loop using moving average filter and multiplier type …
digital controller of a Phase Locked Loop using moving average filter and multiplier type …
PLL performance under frequency fluctuation-compliance with standards for distributed generation connected to the grid
Grid frequency fluctuation from the nominal value is expected by the standards related to
distributed generation (DG) and smart grid (SG) systems. The Phase Locked Loop (PLL) …
distributed generation (DG) and smart grid (SG) systems. The Phase Locked Loop (PLL) …
Implementation aspects of adaptive window moving average filter applied to PLLs—Comparative study
New standards for grid connected distributed generation systems requires operation for
variable grid frequency. This paper discusses implementation details for the adaptive MAV …
variable grid frequency. This paper discusses implementation details for the adaptive MAV …
[图书][B] Analysis and design of a smart-inverter for renewable energy interconnection to the grid
A Reznik - 2013 - search.proquest.com
This Master thesis presents a three phase grid connected DC/AC inverter with active and
reactive power (VAR) control for medium size renewable and distributed DC energy …
reactive power (VAR) control for medium size renewable and distributed DC energy …
dSPACE based implementation of a grid connected smart inverter system
C da Silveira Postiglione… - 2010 IEEE 12th Workshop …, 2010 - ieeexplore.ieee.org
This paper presents the implementation of a grid connected smart inverter using the
dSPACE system as a rapid prototyping solution for laboratory implementation. The dSPACE …
dSPACE system as a rapid prototyping solution for laboratory implementation. The dSPACE …
[PDF][PDF] Adaptive single phase moving average filter PLLs: analysis, design, performance evaluation and comparison
This work analyzes the single-phase Phase Locked Loops using adaptive Moving Average
filter and proposes a discrete time tuning procedure, resulting in faster transient response …
filter and proposes a discrete time tuning procedure, resulting in faster transient response …