Critical review of latent heat storage systems for free cooling in buildings

R Zeinelabdein, S Omer, G Gan - Renewable and Sustainable Energy …, 2018 - Elsevier
Buildings have a major contribution to the global energy consumption. Heating, ventilating
and air conditioning systems (HVAC) are responsible for most of the energy use in buildings …

Review on phase change material based free cooling of buildings—The way toward sustainability

M Thambidurai, K Panchabikesan… - Journal of Energy …, 2015 - Elsevier
The present world energy scenario signifies the importance of renewable energy utilization
and paves the pathway towards green and net zero energy building concepts for a …

Reduction of energy consumption and CO2 emissions of HVAC system in airport terminal buildings

OF Yildiz, M Yilmaz, A Celik - Building and Environment, 2022 - Elsevier
Airport terminal buildings consume more energy than other buildings in an airport due to
their functional and operational characteristics. Heating, ventilation and air conditioning …

Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones

KP Lee, HL Chen - Energy and buildings, 2013 - Elsevier
Based on the climate classification of ASHRAE 90.1 and the required operating environment
conditions for data centers suggested by the ASHRAE Technical Committee TC 9.9, a …

A Review of Phase Change Materials as a Heat Storage Medium for Cooling Applications in the Built Environment

U Masood, M Haggag, A Hassan, M Laghari - Buildings, 2023 - mdpi.com
The air conditioning demand varies significantly in the hot and desert climates of the UAE
due to diurnal temperature variation, seasonal shifts, and occupancy patterns. One of the …

Assessing the applicability of passive cooling and heating techniques through climate factors: An overview

A Tejero-González, M Andrés-Chicote… - … and sustainable energy …, 2016 - Elsevier
A review on climate parameters affecting applicability of passive and low energy heating
and cooling techniques is presented. The study has been developed from existing research …

Potential of air-side economizers for data center cooling: A case study for key Australian cities

J Siriwardana, S Jayasekara, SK Halgamuge - Applied Energy, 2013 - Elsevier
The provision of low cost cooling is challenging due to high energy costs and increasing
heat dissipation volumes from data centers. In Australia, with the introduction of emissions …

A review of building energy retrofit measures, passive design strategies and building regulation for the low carbon development of existing dwellings in the hot …

C Liu, S Sharples, H Mohammadpourkarbasi - Energies, 2023 - mdpi.com
Retrofitting buildings to achieve improved levels of energy performance is a key strategy in
the transition to a low-/net zero carbon future. In China, there has been an enormous growth …

Numerical and experimental investigations on thermal management for data center with cold aisle containment configuration

YT Lee, CY Wen, YC Shih, Z Li, AS Yang - Applied Energy, 2022 - Elsevier
This study proposes the container data center with the featured cold aisle containment
(CAC) as effective thermal control strategy. In design, the overhead downward flow system is …

Effect of climate conditions on the thermodynamic performance of a data center cooling system under water-side economization

AJ Díaz, R Cáceres, R Torres, JM Cardemil… - Energy and …, 2020 - Elsevier
This paper evaluates the potential of water-side economizers in the refrigeration system of
data centers under different climate conditions. Due to the wide range of conditions along …