Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994)
RP Buck, E Lindner - Pure and Applied Chemistry, 1994 - degruyter.com
The rapid growth of interest in the field of ion-selective electrodes (ISEs), within the larger
field of electrochemical sensors based on potentiometric, amperometric, and conductometric …
field of electrochemical sensors based on potentiometric, amperometric, and conductometric …
Potentiometric determination of amprolium drug at a carbon nanotubes/nickel oxide nanoparticles paste electrode
AM Abdel-Raoof, A Elsonbaty, S Abdulwahab… - Microchemical …, 2021 - Elsevier
Nowadays, food safety has become a significant consideration in production and operations
to deal with consumers' negative perceptions and enable organizations to deal with current …
to deal with consumers' negative perceptions and enable organizations to deal with current …
Development of novel potentiometric sensors for determination of tartrazine dye concentration in foodstuff products
HMA Shawish, NA Ghalwa, SM Saadeh… - Food chemistry, 2013 - Elsevier
Tartrazine dye Na3TZ in foodstuff products was determined by a new modified carbon paste
electrode, encoded sensor A, and a coated silver wire electrode, encoded sensor B, based …
electrode, encoded sensor A, and a coated silver wire electrode, encoded sensor B, based …
Carbon paste electrodes in potentiometry: the state of the art and applications in modern electroanalysis (a review)
Z Stanić, S Girousi - Sensing in electroanalysis. K. Kalcher, R. Metelka, I …, 2011 - dk.upce.cz
The development of chemical sensors has received widespread attention during the past
two decades because of their extensive use in environmental monitoring and clinical …
two decades because of their extensive use in environmental monitoring and clinical …
A comparative study of solid and liquid inner contact benzalkonium chloride ion-selective electrode membranes
A comparative study was made between two designs of benzalkonium ion (Bz)-selective
electrodes: a silver-coated (solid contact) called electrode A and a PVC membrane (liquid …
electrodes: a silver-coated (solid contact) called electrode A and a PVC membrane (liquid …
Determination of haloperidol drug in ampoules and in urine samples using a potentiometric modified carbon paste electrode
HMA Shawish, KIA Almonem, SM Saadeh, WS Al-lham - Measurement, 2016 - Elsevier
A modified carbon paste electrode for haloperidol drug based on haloperidol-
phosphomolybdate (HP-PM) as an ion-exchanger dissolved in plasticizer DBP and its …
phosphomolybdate (HP-PM) as an ion-exchanger dissolved in plasticizer DBP and its …
Determination of benzalkonium chloride preservative in pharmaceutical formulation of eye and ear drops using new potentiometric sensors
A novel approach for determination of low concentrations of the preservative, benzalkonium
chloride (BCCl), in pharmaceutical formulation constitutes is presented. New chemically …
chloride (BCCl), in pharmaceutical formulation constitutes is presented. New chemically …
Optimization of tramadol–PVC membrane electrodes using miscellaneous plasticizers and ion-pair complexes
HMA Shawish, SM Saadeh, AR Al-Dalou… - Materials Science and …, 2011 - Elsevier
Effect of the ISE membrane composition on the characteristics of the tramadol–PVC-
electrodes has been investigated. The parameters studied include the effect of the …
electrodes has been investigated. The parameters studied include the effect of the …
Electrochemical oxidation of chlorpheniramine at polytyramine film doped with ruthenium (II) complex: Measurement, kinetic and thermodynamic studies
A solid-state sensor based on polytyramine film deposited at glassy carbon electrode doped
with tris (2, 2′-bipyridyl) Ru (II) complex (Ru/Pty/GCE) was constructed electrochemically. A …
with tris (2, 2′-bipyridyl) Ru (II) complex (Ru/Pty/GCE) was constructed electrochemically. A …
Enhanced sensitivity for Cu (II) by a salicylidine-functionalized polysiloxane carbon paste electrode
HM Abu-Shawish, SM Saadeh, AR Hussien - Talanta, 2008 - Elsevier
A new approach for decreasing the detection limit for a copper (II) ion-selective electrode
(ISE) is presented. The ISE is designed using salicylidine-functionalized polysiloxane in …
(ISE) is presented. The ISE is designed using salicylidine-functionalized polysiloxane in …