[图书][B] Protective relaying of power systems using mathematical morphology
QH Wu, Z Lu, T Ji - 2009 - books.google.com
Page 1 QH Wu Z. Lu⚫ TY Ji power systems Protective Relaying of Power Systems Using
Mathematical Morphology Springer Page 2 Power Systems Page 3 QH Wu Z. Lu· TY Ji • …
Mathematical Morphology Springer Page 2 Power Systems Page 3 QH Wu Z. Lu· TY Ji • …
An efficient compensation algorithm for current transformer saturation effects
J Pan, K Vu, Y Hu - IEEE Transactions on Power delivery, 2004 - ieeexplore.ieee.org
Current transformer (CT) saturation leads to inaccurate current measurement and, therefore,
may cause malfunction of protective relays and control devices that use currents as input …
may cause malfunction of protective relays and control devices that use currents as input …
Correction of saturated current transformers secondary current using ANNs
H Khorashadi-Zadeh… - IEEE Transactions on …, 2005 - ieeexplore.ieee.org
Current transformers (CTs) provide instrument-level current signals to meters and protective
relays. Protective relays' accuracy and performance are directly related to steady-state and …
relays. Protective relays' accuracy and performance are directly related to steady-state and …
Phasor estimation in the presence of DC offset and CT saturation
SR Nam, JY Park, SH Kang… - IEEE transactions on …, 2009 - ieeexplore.ieee.org
A hybrid algorithm for phasor estimation is proposed that is immune to DC offset and current
transformer (CT) saturation problems. The algorithm utilizes partial sum (PS)-based and …
transformer (CT) saturation problems. The algorithm utilizes partial sum (PS)-based and …
ANFIS-based compensation algorithm for current-transformer saturation effects
K Erenturk - IEEE Transactions on Power Delivery, 2008 - ieeexplore.ieee.org
This paper proposes an efficient compensation algorithm based on an adaptive network-
based fuzzy inference system capable of converting a sampled current waveform that is …
based fuzzy inference system capable of converting a sampled current waveform that is …
A differential relay for power transformers using intelligent tools
EC Segatto, DV Coury - IEEE Transactions on Power Systems, 2006 - ieeexplore.ieee.org
This paper presents alternative approaches using artificial neural networks (ANNs) for the
protection of power transformers. A complete protection scheme was implemented. An ANN …
protection of power transformers. A complete protection scheme was implemented. An ANN …
Current transformer saturation compensator by using negative voltage feedback
M Delzendeh, HK Karegar - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
Current Transformers (CTs) saturation leads to distortion of current waveform and
operational malfunction of protection relays. This paper introduces a practical and simple …
operational malfunction of protection relays. This paper introduces a practical and simple …
Compensation of CT distorted secondary current waveform in online conditions
F Haghjoo, MH Pak - IEEE Transactions on Power delivery, 2015 - ieeexplore.ieee.org
Current-transformer (CT) saturation phenomenon impacts the performance of the current-
based protective relays and leads them to malfunction; so detecting and resolving such …
based protective relays and leads them to malfunction; so detecting and resolving such …
Detection of Current Transformer Saturation Based on Machine Learning
One of the tasks in the operation of electric power systems is the correct functioning of the
protection system and emergency automation algorithms. Instrument voltage and current …
protection system and emergency automation algorithms. Instrument voltage and current …
Evaluation of numerical time overcurrent relay performance for current transformer saturation compensation methods
GL Macieira, ALM Coelho - Electric Power Systems Research, 2017 - Elsevier
Current transformer (CT) core has non-linear magnetic characteristics and may achieve high
flux values when exposed to high fault currents. In this case, the CT primary current is not …
flux values when exposed to high fault currents. In this case, the CT primary current is not …