Emerging trends in CV flow visualization
PP Sengupta, G Pedrizzetti, PJ Kilner… - JACC: Cardiovascular …, 2012 - jacc.org
Blood flow patterns are closely linked to the morphology and function of the cardiovascular
system. These patterns reflect the exceptional adaptability of the cardiovascular system to …
system. These patterns reflect the exceptional adaptability of the cardiovascular system to …
[HTML][HTML] Experimental assessment of flow fields associated with heart valve prostheses using particle image velocimetry (PIV): recommendations for best practices
V Raghav, S Sastry, N Saikrishnan - Cardiovascular engineering and …, 2018 - Springer
Experimental flow field characterization is a critical component of the assessment of the
hemolytic and thrombogenic potential of heart valve substitutes, thus it is important to identify …
hemolytic and thrombogenic potential of heart valve substitutes, thus it is important to identify …
Vorticity dynamics of a bileaflet mechanical heart valve in an axisymmetric aorta
LP Dasi, L Ge, HA Simon, F Sotiropoulos… - Physics of …, 2007 - pubs.aip.org
We present comprehensive particle image velocimetry measurements and direct numerical
simulation (DNS) of physiological, pulsatile flow through a clinical quality bileaflet …
simulation (DNS) of physiological, pulsatile flow through a clinical quality bileaflet …
Direct numerical simulation of the pulsatile flow through an aortic bileaflet mechanical heart valve
MD De Tullio, A Cristallo, E Balaras… - Journal of Fluid …, 2009 - cambridge.org
This work focuses on the direct numerical simulation of the pulsatile flow through a bileaflet
mechanical heart valve under physiological conditions and in a realistic aortic root …
mechanical heart valve under physiological conditions and in a realistic aortic root …
Effect of the prosthetic mitral valve on vortex dynamics and turbulence of the left ventricular flow
G Querzoli, S Fortini, A Cenedese - Physics of fluids, 2010 - pubs.aip.org
Mechanical heart valves implanted in mitral position have a great effect on the ventricular
flow. Changes include alteration of the dynamics of the vortical structures generated during …
flow. Changes include alteration of the dynamics of the vortical structures generated during …
Combined experimental and numerical analysis of the flow structure into the left ventricle
F Domenichini, G Querzoli, A Cenedese… - Journal of …, 2007 - Elsevier
Fluid dynamics is used for diagnosis in cardiology only to a partial extent. Indeed several
aspects of cardiac flows and their relation with pathophysiology are unknown. The flow that …
aspects of cardiac flows and their relation with pathophysiology are unknown. The flow that …
[HTML][HTML] Role of computational simulations in heart valve dynamics and design of valvular prostheses
KB Chandran - Cardiovascular engineering and technology, 2010 - Springer
Computational simulations are playing an increasingly important role in enhancing our
understanding of the normal human physiological function, etiology of diseased states …
understanding of the normal human physiological function, etiology of diseased states …
Particle image velocimetry of 3D-printed anatomical blood vascular models affected by atherosclerosis
A Antonowicz, K Wojtas, Ł Makowski, W Orciuch… - Materials, 2023 - mdpi.com
Improvements in the diagnosis and treatment of cardiovascular diseases facilitate a better
understanding of the ongoing process. The study of biomedical fluid dynamics using non …
understanding of the ongoing process. The study of biomedical fluid dynamics using non …
A critical review on advanced velocity measurement techniques in pulsating flows
M Nabavi, K Siddiqui - Measurement science and technology, 2010 - iopscience.iop.org
Velocity measurement in pulsating flows is more difficult than that in steady flows. One
problem follows from the necessity to synchronize the measuring instrument with the …
problem follows from the necessity to synchronize the measuring instrument with the …
[HTML][HTML] Tomographic PIV behind a prosthetic heart valve
D Hasler, A Landolt, D Obrist - Experiments in Fluids, 2016 - Springer
The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was
measured using tomographic particle image velocimetry. Two digital cameras were used …
measured using tomographic particle image velocimetry. Two digital cameras were used …