Highly Accurate Derivatives for LCL-Filtered Grid Converter With Capacitor Voltage Active Damping
The middle capacitor voltage of an LCL-filter, if fed back for synchronization, can be used for
active damping. An extra sensor for measuring the capacitor current is then avoided …
active damping. An extra sensor for measuring the capacitor current is then avoided …
Robust active damping methods for LCL filter-based grid-connected converters
MB Saïd-Romdhane, MW Naouar… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
Grid-connected converters (GcCs) employ LCL filters instead of simple L filters in order to
meet new grid codes and their on-going changes in the near future. Active damping …
meet new grid codes and their on-going changes in the near future. Active damping …
A robust adaptive one sample ahead preview controller for grid-injected currents of a grid-tied power converter with an LCL filter
DMC Milbradt, GV Hollweg… - International Journal of …, 2022 - Elsevier
This paper presents the development of a discrete-time Robust Adaptive One Sample
Ahead Preview controller, based on the combination of a Robust Model Reference Adaptive …
Ahead Preview controller, based on the combination of a Robust Model Reference Adaptive …
Internal model based smooth transition of a three-phase inverter between islanded and grid-connected modes
S Yazdani, M Ferdowsi… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Recent technical advances in control, protection and interconnection of distributed power
generation units imply that it is practically viable and economically profitable to keep them as …
generation units imply that it is practically viable and economically profitable to keep them as …
A Switched-Capacitor Multilevel Inverter With Modified Pulsewidth Modulation and Active DC-Link Capacitor Voltage Balancing
Although switched-capacitor (SC) multilevel inverters (MLIs) offer self-voltage balancing of
flying capacitors and voltage gain higher than unity, the advantages come at the cost of high …
flying capacitors and voltage gain higher than unity, the advantages come at the cost of high …
Variable structure control in natural frame for three-phase grid-connected inverters with LCL filter
This paper presents a variable structure control in natural frame for a three-phase gird-
connected voltage-source inverter with LCL filter. The proposed control method is based on …
connected voltage-source inverter with LCL filter. The proposed control method is based on …
Robust grid-current-feedback resonance suppression method for LCL-type grid-connected inverter connected to weak grid
X Zhou, L Zhou, Y Chen, Z Shuai… - IEEE Journal of …, 2018 - ieeexplore.ieee.org
In this paper, a robust grid-current-feedback resonance suppression (GCFRS) method for
LCL-type grid-connected inverters is proposed to enhance system damping without …
LCL-type grid-connected inverters is proposed to enhance system damping without …
Capacitor Voltage Damping Based on Parallel Feedforward Compensation Method for LCL-Filter Grid-Connected Inverter
Active damping is a popular approach to suppress the resonance in LCL-filtered grid-
connected inverter owing to lossless damping and efficient system design. In capacitor …
connected inverter owing to lossless damping and efficient system design. In capacitor …
Linear ADRC direct current control of grid‐connected inverter with LCL filter for both active damping and grid voltage induced current distortion suppression
B Wang, Z Shen, H Liu, J Hu - IET Power Electronics, 2018 - Wiley Online Library
The conversion and utilisation of renewable energy generations often require grid‐
connected inverters. When applying LCL filter to remove power electronic chopping …
connected inverters. When applying LCL filter to remove power electronic chopping …
Stability of LCL-filtered grid-connected inverters with capacitor current feedback active damping considering controller time delays
W Xia, J Kang - Journal of Modern Power Systems and Clean …, 2017 - ieeexplore.ieee.org
This paper investigates the stability of LCL-fil-tered grid-connected inverters with capacitor
current feedback (CCF) active damping. The impact of time delays in the digital controller on …
current feedback (CCF) active damping. The impact of time delays in the digital controller on …