A review of current and new measurement techniques used in hot die forging processes

M Hawryluk, J Ziemba… - Measurement and …, 2017 - journals.sagepub.com
The work presents the possibilities of applying modern measuring techniques, classic and
coordinate measuring techniques in the forging industry (various stages of technological …

Possibilities of application measurement techniques in hot die forging processes

M Hawryluk, J Ziemba - Measurement, 2017 - Elsevier
The article is a review presenting the possibilities of applying modern measuring techniques
in the forging industry by using various measuring tools, instruments and machines applied …

Material loss at the taper junction of retrieved large head metal‐on‐metal total hip replacements

AK Matthies, R Racasan, P Bills, L Blunt… - Journal of …, 2013 - Wiley Online Library
It has been speculated that material loss, either as corrosion or wear, at the head–stem taper
junction is implicated in the high revision rates reported for metal‐on‐metal total hip …

Application of the 3D reverse scanning method in the analysis of tool wear and forging defects

M Hawryluk, J Ziemba - Measurement, 2018 - Elsevier
This article refers to the application of the 3D reverse scanning method for the purpose of
analyzing the progressing wear of forging tools as well as detecting forging defects in …

Factors associated with trunnionosis in the metal-on-metal pinnacle hip

HS Hothi, AP Eskelinen, R Berber, OS Lainiala… - The Journal of …, 2017 - Elsevier
Background Trunnionosis of the tapered head-stem junction of total hip arthroplasties, either
through corrosion or mechanical wear, has been implicated in early implant failure. Retrieval …

A new approach using palm olein, palm kernel oil, and palm fatty acid distillate as alternative biolubricants: improving tribology in metal-on-metal contact

DM Razak, S Syahrullail, N Sapawe, Y Azli… - Tribology …, 2015 - Taylor & Francis
Metal-on-metal (MoM) hip replacements are commonly used hip implants. However, one of
the issues under debate is the interference of friction and wear. The purpose of this …

Running-in behavior on single-mobility total hip arthroplasty

T Hidayat, J Jamari, AP Bayuseno, R Ismail… - Medical Engineering & …, 2022 - Elsevier
Total hip arthroplasty is a short-term solution for replacing a damaged hip joint with synthetic
biomaterials. Total hip arthroplasty comes in two flavors: single and dual mobility …

Experimental investigation on wear map evolution of ceramic-on-UHMWPE hip prosthesis

L Mattei, F Di Puccio, E Ciulli, A Pauschitz - Tribology International, 2020 - Elsevier
In the literature, wear damage of hip prostheses is typically expressed as volumetric wear.
Details on wear distribution are rarely provided despite being fundamental to better …

Influence of stem type on material loss at the metal-on-metal pinnacle taper junction

HS Hothi, RK Whittaker, JM Meswania… - Proceedings of the …, 2015 - journals.sagepub.com
The clinical importance of material loss at the head–stem junction is unknown. Comparison
of retrievals with different stem types can provide the opportunity to understand the …

Ceramic femoral heads exhibit lower wear rates compared to cobalt chrome: a meta-analysis

KC Mertz, JW Yang, BC Chung, X Chen… - The Journal of …, 2023 - Elsevier
Background Wear between the femoral head and acetabular liners continues to limit the
longevity of total hip arthroplasty implants despite advances in implant materials. The …