A machine learning-based formulation for predicting shear capacity of squat flanged RC walls
The squat flanged reinforced concrete (RC) walls have been widely utilized in nuclear
power plant and building structures. Nevertheless, the empirical equations in current design …
power plant and building structures. Nevertheless, the empirical equations in current design …
Performance of precast shear wall connections under monotonic and cyclic loading: a state-of-the-art review
S Hemamalini, R Vidjeapriya, KP Jaya - Iranian Journal of Science and …, 2021 - Springer
Industrialized building system (IBS) is the term used to represent the concept of
prefabrication, and it has been widely used worldwide. In the last few decades, all the …
prefabrication, and it has been widely used worldwide. In the last few decades, all the …
Mechanics-guided genetic programming expression for shear-strength prediction of squat reinforced concrete walls with boundary elements
A Gondia, M Ezzeldin… - Journal of Structural …, 2020 - ascelibrary.org
Squat reinforced concrete shear walls with boundary elements (SRCSW-BE) are used in
special structures (eg, nuclear facilities) to resist lateral seismic loads. However, several …
special structures (eg, nuclear facilities) to resist lateral seismic loads. However, several …
[PDF][PDF] Seismic behavior of low aspect ratio reinforced concrete shear walls
B Luna, A Whittaker, J Rivera - 2013 - repository.lib.ncsu.edu
Although low aspect ratio shear walls are widely used in safety-related nuclear structures,
their hysteretic behavior, including peak strength and effective elastic stiffness, has not been …
their hysteretic behavior, including peak strength and effective elastic stiffness, has not been …
Lateral resistances of RC shear walls controlled by shear and sliding failure modes under axial tension
This study delved into the shear and sliding performances of RC shear walls subjected to
combined axial tension and lateral shear, which may occur at the bottom of high-rise …
combined axial tension and lateral shear, which may occur at the bottom of high-rise …
Gene expression programming for estimating shear strength of RC squat wall
The flanged, barbell, and rectangular squat reinforced concrete (RC) walls are broadly used
in low-rise commercial and highway under and overpasses. The shear strength of squat …
in low-rise commercial and highway under and overpasses. The shear strength of squat …
Tests on seismic and shear performance of RC shear walls under alternating axial tensile and compressive loads
Under strong earthquakes, reinforced concrete (RC) shear walls at the bottom of high-rise
buildings may experience an internal force state of alternating tension-shear (-bending) and …
buildings may experience an internal force state of alternating tension-shear (-bending) and …
Peak Strength of Shear-Critical Reinforced Concrete Walls.
BN Luna, AS Whittaker - ACI Structural Journal, 2019 - search.ebscohost.com
Twelve low-aspect-ratio rectangular reinforced concrete (RC) walls were built and tested
under reversed cyclic loading at the University at Buffalo. One of the objectives of the …
under reversed cyclic loading at the University at Buffalo. One of the objectives of the …
[HTML][HTML] 工字形钢筋混凝土矮墙抗剪承载力研究
马佳星, 陈柯宇, 王银辉, 李兵 - 工程力学, 2021 - pubs.cstam.org.cn
工字形钢筋混凝土(RC) 矮墙在双主轴向均具有较高的强度和刚度, 常用于低,
中层建筑及核电站设施中. 现有规范在预测工字形RC 矮墙抗剪承载力时存在考虑参数不足 …
中层建筑及核电站设施中. 现有规范在预测工字形RC 矮墙抗剪承载力时存在考虑参数不足 …
Assessment of Shear Strength Models for Squat Rectangular Reinforced Concrete Shear Walls
DX Nguyen, XH Vu, KVT Nguyen… - Engineering, Technology & …, 2024 - etasr.com
The shear strength is a critical parameter in the design of Reinforced Concrete (RC) shear
walls subjected to lateral loads. Numerous design codes and published studies have …
walls subjected to lateral loads. Numerous design codes and published studies have …