Single photon emission computed tomography (SPECT) myocardial perfusion imaging guidelines: instrumentation, acquisition, processing, and interpretation
S Dorbala, K Ananthasubramaniam… - Journal of Nuclear …, 2018 - Elsevier
The purpose of this document is to update the “ASNC Imaging Guidelines for Nuclear
Cardiology Procedures: Single photon-emission computed tomography” 1 in several areas …
Cardiology Procedures: Single photon-emission computed tomography” 1 in several areas …
The performance of non-invasive tests to rule-in and rule-out significant coronary artery stenosis in patients with stable angina: a meta-analysis focused on post-test …
Aims To determine the ranges of pre-test probability (PTP) of coronary artery disease (CAD)
in which stress electrocardiogram (ECG), stress echocardiography, coronary computed …
in which stress electrocardiogram (ECG), stress echocardiography, coronary computed …
Gated myocardial perfusion SPECT: basic principles, technical aspects, and clinical applications
AK Paul, HA Nabi - Journal of nuclear medicine technology, 2004 - Soc Nuclear Med
Electrocardiographically gated myocardial perfusion SPECT (GSPECT) is a state-of-the-art
technique for the combined evaluation of myocardial perfusion and left ventricular function …
technique for the combined evaluation of myocardial perfusion and left ventricular function …
Incremental value of combined perfusion and function over perfusion alone by gated SPECT myocardial perfusion imaging for detection of severe three-vessel …
RSL Lima, DD Watson, AR Goode, MS Siadaty… - Journal of the American …, 2003 - jacc.org
Objectives: We hypothesized that combining functional assessment to perfusion enhances
the ability of electrocardiographic gating Tc-99m sestamibi single photon emission …
the ability of electrocardiographic gating Tc-99m sestamibi single photon emission …
Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach
G Germano, PB Kavanagh, PJ Slomka… - Journal of nuclear …, 2007 - Elsevier
Cedars-Sinai's approach to the automation of gated perfusion single photon emission
computed tomography (SPECT) imaging is based on the identification of key procedural …
computed tomography (SPECT) imaging is based on the identification of key procedural …
The prognostic value of ECG-gated SPECT imaging in patients undergoing stress Tc-99m sestamibi myocardial perfusion imaging
MI Travin, GV Heller, LL Johnson, D Katten… - Journal of nuclear …, 2004 - Springer
Background The ability of stress radionuclide myocardial perfusion imaging to predict
adverse cardiac events is well accepted. As left ventricular systolic function has also been …
adverse cardiac events is well accepted. As left ventricular systolic function has also been …
Diagnostic safety of a machine learning-based automatic patient selection algorithm for stress-only myocardial perfusion SPECT
Background Stress-only myocardial perfusion imaging (MPI) markedly reduces radiation
dose, scanning time, and cost. We developed an automated clinical algorithm to safely …
dose, scanning time, and cost. We developed an automated clinical algorithm to safely …
The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging
V Go, MR Bhatt, RC Hendel - Journal of Nuclear Medicine, 2004 - Soc Nuclear Med
Since the development of gated SPECT imaging approximately 10 y ago, this technique is
now almost universally used as an adjunct for radionuclide perfusion imaging, enabling the …
now almost universally used as an adjunct for radionuclide perfusion imaging, enabling the …
Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” …
EG DePuey, R Gadiraju, J Clark, L Thompson… - Journal of Nuclear …, 2008 - Elsevier
OBJECTIVES: Compared to filtered back projection (FBP), OSEM with resolution recovery
(OSEM-RR) and wide beam reconstruction (WBR)(UltraSPECT Ltd.), which resolve …
(OSEM-RR) and wide beam reconstruction (WBR)(UltraSPECT Ltd.), which resolve …
Improved accuracy of myocardial perfusion SPECT for the detection of coronary artery disease using a support vector machine algorithm
R Arsanjani, Y Xu, D Dey, M Fish… - Journal of Nuclear …, 2013 - Soc Nuclear Med
We aimed to improve the diagnostic accuracy of automatic myocardial perfusion SPECT
(MPS) interpretation analysis for the prediction of coronary artery disease (CAD) by …
(MPS) interpretation analysis for the prediction of coronary artery disease (CAD) by …