Assessment of true intraocular pressure: the gap between theory and practical data
E Chihara - Survey of ophthalmology, 2008 - Elsevier
A precise assessment of the intraocular pressure (IOP) is crucial for diagnosis and decision
making regarding treatment modalities in patients with glaucoma. Recent epidemiologic …
making regarding treatment modalities in patients with glaucoma. Recent epidemiologic …
Intraocular pressure measurement: A review
F Da Silva, M Lira - Survey of Ophthalmology, 2022 - Elsevier
Glaucoma is the leading cause of irreversible blindness, affecting around 80 million people
worldwide. Glaucoma is a multifactorial disease of poorly understood pathogenesis, with …
worldwide. Glaucoma is a multifactorial disease of poorly understood pathogenesis, with …
The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann …
PA Tonnu, T Ho, T Newson, A El Sheikh… - British Journal of …, 2005 - bjo.bmj.com
Aims: To evaluate the influence of central corneal thickness (CCT) on intraocular pressure
(IOP) measurements made with the Goldmann applanation tonometer (GAT), Tono-Pen XL …
(IOP) measurements made with the Goldmann applanation tonometer (GAT), Tono-Pen XL …
Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients
P Brusini, ML Salvetat, M Zeppieri, C Tosoni… - Journal of …, 2006 - journals.lww.com
Purpose To compare the intraocular pressure (IOP) readings taken with the new ICare
tonometer and with the Goldmann applanation tonometer (GAT) and to evaluate the …
tonometer and with the Goldmann applanation tonometer (GAT) and to evaluate the …
The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
A Kotecha, ET White, JM Shewry… - British Journal of …, 2005 - bjo.bmj.com
Aims: To establish the effects of central corneal thickness (CCT) on intraocular pressure
(IOP) measured with a prototype Pascal dynamic contour tonometer (DCT), to evaluate the …
(IOP) measured with a prototype Pascal dynamic contour tonometer (DCT), to evaluate the …
Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure
AT Broman, NG Congdon, K Bandeen-Roche… - Journal of …, 2007 - journals.lww.com
Purpose To estimate the relationships between ocular parameters and tonometrically
measured intraocular pressure (IOP), to determine the influence of ocular parameters on …
measured intraocular pressure (IOP), to determine the influence of ocular parameters on …
Diurnal variation of corneal shape and thickness
SA Read, MJ Collins - Optometry and Vision Science, 2009 - journals.lww.com
Purpose. To investigate associations between the diurnal variation in a range of corneal
parameters, including anterior and posterior corneal topography, and regional corneal …
parameters, including anterior and posterior corneal topography, and regional corneal …
Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry
BA Francis, A Hsieh, MY Lai, V Chopra, F Pena, S Azen… - Ophthalmology, 2007 - Elsevier
PURPOSE: To compare the measurements of intraocular pressure (IOP) with Goldmann
applanation tonometry (GAT) and dynamic contour tonometry (DCT) and the effects of …
applanation tonometry (GAT) and dynamic contour tonometry (DCT) and the effects of …
Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry
C Kaufmann, LM Bachmann, YC Robert… - Archives of …, 2006 - jamanetwork.com
Objectives To test whether dynamic contour tonometry yields ocular pulse amplitude (OPA)
measurements that are independent of corneal thickness and curvature, and to assess …
measurements that are independent of corneal thickness and curvature, and to assess …
Intraocular pressure measurement-comparison of dynamic contour tonometry and goldmann applanation tonometry
E Schneider, F Grehn - Journal of glaucoma, 2006 - journals.lww.com
Purpose: The dynamic contour tonometer (DCT, Pascal tonometer, Swiss Microtechnology
AG, Port, Switzerland) was recently introduced as a new method of intraocular pressure …
AG, Port, Switzerland) was recently introduced as a new method of intraocular pressure …